Troubleshooting

Normal Stage of Operation

SYMPTOM

POSSIBLE PROBLEMS

SERVICE

 

 

 

Tool operates properly, but fasteners do not

Work-contacting element requires adjustment.

Adjust work contacting element.

drive fully.

 

 

Fuel cell is low.

Check fuel cell and replace as required.

 

 

 

 

 

There may be loss of seal in combustion

Press work contacting element against

 

chamber.

workpiece for one minute. Pull trigger. If

 

 

fastener does not drive, there is a leak that

 

 

requires service.

 

 

 

Tool operates properly, but fasteners are

Work-contacting element is not adjusted

Adjust work-contacting element. Readjust

sometimes over-driven, and sometimes

properly for the type of material being

as required when material density or

under-driven.

fastened.

thickness of material being fastened

 

 

changes.

 

 

 

Tool operates, but no fastener is driven.

Wrong fasteners being used.

Use only fasteners meeting Paslode®

 

 

specifications. Check Fasteners and

 

 

Applications section for fastener types and

 

 

sizes recommended for use in Impulse tool.

 

 

 

 

Follower not properly engaged behind fastener

Position follower behind fastener strip and

 

strip.

engage strip.

 

 

 

 

Jammed fastener.

Clear jam.

 

 

 

Tool operates erratically or appears to be

Fuel cell is low.

Check fuel cell.

losing power - tool indicator light is green.

 

 

Spark plug wire is loose.

Check spark plug wire.

 

 

 

 

 

Air filter is dirty, causing tool to overheat.

Remove air filter and clean. Use soap and

 

 

water to remove stubborn debris.

 

 

 

 

Tool is dirty.

Clean tool.

 

 

 

Tool operated and drove fasteners, but

Built-up dirt and debris on driver blade or in

Clean driver blade and nose bore with

driver blade did not return to up position.

nose bore.

degreaser cleaner.

 

 

 

 

Tool is dirty.

Clean tool.

 

 

 

Combustion chamber does not drop after

 

Clean track or replace work-contacting

Work-contacting element is bent, or is dirty.

element.

tool cycles.

 

 

 

 

 

If nailer will not operate after following the above service directions, return the tool to an authorized Paslode® representative for service.

For the nearest Paslode® representative call 1-800-682-3428.

For Technical support call 1-800-222-6990.