Installation
Electrical Requirements | This cooker must not be used free standing. |
| ||||||||
GB | ||||||||||
For your own safety, we recommend that your cooker | Note; This cooker must not be fitted on a platform. | |||||||||
| ||||||||||
is installed by a competent person such as one who |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
is registered with NICEIC (National Inspection | FINAL INSTALLATION |
| ||||||||
Council for Electrical Installation Contracting). The | a. Ensure that the adjacent cabinets and the gap |
| ||||||||
cooker should be installed in accordance with the |
| between them have dimensions in accordance with |
| |||||||
latest edition of the IEE Regulations. |
| the diagram. |
| |||||||
| b. Assemble the plastic plugs provided into the fixing |
| ||||||||
Warning: This appliance must be earthed. |
| brackets. See diagram. |
| |||||||
| c. Fix the fixing brackets to the sides of the adjacent |
| ||||||||
Electrical Connections |
| cabinets so that the centre line of the brackets are |
| |||||||
The installer must check that the voltage shown on |
| 570mm above the top of the plinth line and the front |
| |||||||
the rating plate corresponds with the house |
| face of the plastic plug is level with the front face |
| |||||||
electricity supply. The cooker must be supplied via |
| of the cabinet sides. See diagram. |
| |||||||
a suitable double pole isolating switch, having a | d. Adjust the feet on the cooker to their minimum |
| ||||||||
contact separation of at least 3mm in all poles |
| position, i.e. fully screwed in. |
| |||||||
placed in a readily accessible position adjacent to | e. Slide the cooker centrally into the space between |
| ||||||||
the cooker. If the cooker is to be wired into a |
| the cabinets ensuring the following: |
| |||||||
connector unit, this may be positioned behind the |
| i) The gap between the cabinet sides and the |
| |||||||
cooker providing the following requirements are met: |
|
| cooker is even along the length of the cabinet |
| ||||||
i) The connector unit must not project from the wall |
|
| sides. |
| ||||||
more than 25mm. |
| ii) The cable is routed away from any vents in the |
| |||||||
ii) The top of the connector must not be more than |
|
| rear panel and is not trapped between the cooker |
| ||||||
130mm above floor level. |
|
| and the wall, adjacent cabinets or under the feet |
| ||||||
Remove the terminal cover at the rear base of the | f. | Adjust the feet using an open ended spanner until |
| |||||||
cooker. Pass the cable through the cable clamp and |
| the bottom of the cooker door is in line with the top |
| |||||||
connect to the appropriate terminals provided. |
| of the plinth. Using a spirit level, check that the |
| |||||||
Allow sufficient cable for any future servicing. |
| cooker is level in all directions. |
| |||||||
Tighten the screws on the cable clamp and replace | g. Check that the plinth can be fitted. If necessary re |
| ||||||||
the cover. Make main connections in the connector |
| - adjust the feet and check that the cooker is level. |
| |||||||
unit or cooker control unit. This appliance conforms |
| Then lock the feet into position by tightening the |
| |||||||
to B.S. EN 55014 regarding suppression of Radio |
| lock nut using an open ended spanner. |
| |||||||
and Television reception interference. | h. Open the top oven door and fix the cooker to the |
| ||||||||
A double Pole control switch having a minimum |
| brackets through the holes in the side trims. |
| |||||||
rating of 32 amps should be used to feed the cooker | i. | Fix the plinth in position. |
| |||||||
using a suitably rated cable. Where a hob is fitted | j. | Ensure that there is a minimum gap of 1mm |
| |||||||
adjacent to or over the cooker, a 45 amp Double |
| between the cooker side trim and the adjacent |
| |||||||
Pole control switch should be used to feed both |
| cabinet doors or drawer fronts. |
| |||||||
units via separate suitably rated cables. | k. If a hob is to be installed directly above the cooker |
| ||||||||
We recommend a minimum of 4mm2 PVC insulated |
| it must not project downwards more than 20mm |
| |||||||
twin and earth cable conforming to B.S. 6004 for |
| below the underside of the work top. Any projection |
| |||||||
connection of each appliance. |
| of more than 10mm must not project more than |
| |||||||
In all cases adhere to routing details (see fig. 5). |
| 500mm from the wall. |
| |||||||
This appliance must not be installed over any other | Fig. 5 |
| ||||||||
appliance that generates heat such as a plinth heater. |
| |||||||||
|
|
|
|
|
|
|
|
| ||
Note: Due to many different types of installation, a |
|
|
|
|
|
|
|
|
| |
mains cable is not supplied with this product. The |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
installer will fit the correct type and length of cable. |
|
|
|
|
|
|
|
|
| |
GENERAL |
|
|
|
|
|
|
|
|
| |
The appliance is designed to be mounted on a floor |
|
|
|
|
|
|
|
|
| |
between two adjacent cabinets. |
|
|
|
|
|
|
|
|
| |
The cabinets must be securely fixed to the wall and |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
the cooker securely fixed to the cabinets. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
21