Installation

Installation

Electrical Requirements

This cooker must not be used free standing.

 

GB

For your own safety, we recommend that your cooker

Note; This cooker must not be fitted on a platform.

 

is installed by a competent person such as one who

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is registered with NICEIC (National Inspection

FINAL INSTALLATION

 

Council for Electrical Installation Contracting). The

a. Ensure that the adjacent cabinets and the gap

 

cooker should be installed in accordance with the

 

between them have dimensions in accordance with

 

latest edition of the IEE Regulations.

 

the diagram.

 

 

b. Assemble the plastic plugs provided into the fixing

 

Warning: This appliance must be earthed.

 

brackets. See diagram.

 

 

c. Fix the fixing brackets to the sides of the adjacent

 

Electrical Connections

 

cabinets so that the centre line of the brackets are

 

The installer must check that the voltage shown on

 

570mm above the top of the plinth line and the front

 

the rating plate corresponds with the house

 

face of the plastic plug is level with the front face

 

electricity supply. The cooker must be supplied via

 

of the cabinet sides. See diagram.

 

a suitable double pole isolating switch, having a

d. Adjust the feet on the cooker to their minimum

 

contact separation of at least 3mm in all poles

 

position, i.e. fully screwed in.

 

placed in a readily accessible position adjacent to

e. Slide the cooker centrally into the space between

 

the cooker. If the cooker is to be wired into a

 

the cabinets ensuring the following:

 

connector unit, this may be positioned behind the

 

i) The gap between the cabinet sides and the

 

cooker providing the following requirements are met:

 

 

cooker is even along the length of the cabinet

 

i) The connector unit must not project from the wall

 

 

sides.

 

more than 25mm.

 

ii) The cable is routed away from any vents in the

 

ii) The top of the connector must not be more than

 

 

rear panel and is not trapped between the cooker

 

130mm above floor level.

 

 

and the wall, adjacent cabinets or under the feet

 

Remove the terminal cover at the rear base of the

f.

Adjust the feet using an open ended spanner until

 

cooker. Pass the cable through the cable clamp and

 

the bottom of the cooker door is in line with the top

 

connect to the appropriate terminals provided.

 

of the plinth. Using a spirit level, check that the

 

Allow sufficient cable for any future servicing.

 

cooker is level in all directions.

 

Tighten the screws on the cable clamp and replace

g. Check that the plinth can be fitted. If necessary re

 

the cover. Make main connections in the connector

 

- adjust the feet and check that the cooker is level.

 

unit or cooker control unit. This appliance conforms

 

Then lock the feet into position by tightening the

 

to B.S. EN 55014 regarding suppression of Radio

 

lock nut using an open ended spanner.

 

and Television reception interference.

h. Open the top oven door and fix the cooker to the

 

A double Pole control switch having a minimum

 

brackets through the holes in the side trims.

 

rating of 32 amps should be used to feed the cooker

i.

Fix the plinth in position.

 

using a suitably rated cable. Where a hob is fitted

j.

Ensure that there is a minimum gap of 1mm

 

adjacent to or over the cooker, a 45 amp Double

 

between the cooker side trim and the adjacent

 

Pole control switch should be used to feed both

 

cabinet doors or drawer fronts.

 

units via separate suitably rated cables.

k. If a hob is to be installed directly above the cooker

 

We recommend a minimum of 4mm2 PVC insulated

 

it must not project downwards more than 20mm

 

twin and earth cable conforming to B.S. 6004 for

 

below the underside of the work top. Any projection

 

connection of each appliance.

 

of more than 10mm must not project more than

 

In all cases adhere to routing details (see fig. 5).

 

500mm from the wall.

 

This appliance must not be installed over any other

Fig. 5

 

appliance that generates heat such as a plinth heater.

 

 

 

 

 

 

 

 

 

 

Note: Due to many different types of installation, a

 

 

 

 

 

 

 

 

 

mains cable is not supplied with this product. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installer will fit the correct type and length of cable.

 

 

 

 

 

 

 

 

 

GENERAL

 

 

 

 

 

 

 

 

 

The appliance is designed to be mounted on a floor

 

 

 

 

 

 

 

 

 

between two adjacent cabinets.

 

 

 

 

 

 

 

 

 

The cabinets must be securely fixed to the wall and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the cooker securely fixed to the cabinets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 