Electrical connection

!Ovens with a three-pole power supply cable are designed to operate with alternated current at the supply frequency and voltage indicated on the data plate (at the bottom of the oven dashboard). The earthing conductor of the cable is the yellow-green conductor.

Two types of connection are provided:

Connection n° 1

Connect Brown wire to terminal marked “L” or

coloured Red. Connect Blue wire to terminal marked GB “N” or coloured Black. If a 13 amp plug (BS 1363) is

used it must be fitted with a 13 amp fuse.

A 15 amp plug must be protected by a 15 amp fuse, either in the plug or adaptor or at the distribution board.If you are in any doubt about the electrical supply to your machine, consult a qualified electrician before use.

How to connect an alternative plug

Connecting the power supply cable to the mains.

Fit a normalized plug to the cable, which corresponds to the load indicated on the data plate; if the cooker is connected directly to the mains, an omnipolar circuit-breaker with a minimum opening of 3 mm between the contacts, suitable for the load indicated and complying with current directives, must be installed between the appliance and the mains (the earthing wire must not be interrupted by the circuit-breaker). The power supply cable must be

The wires in this mains lead are coloured in accordance with the following code: BLUE“NEUTRAL” (N) BROWN “LIVE” (L)

GREEN AND YELLOW “EARTH” (E)

GREEN &

YELLOW

BROWN

BLUE

13 amp fuse

CROSS-BAR CORD GRIP

positioned so that it does not exceed room temperature by 50°C at any point of its length. Before making the connection check that:

the circuit breakers or fuses of the home system can support appliance load (see data plate);

the power supply system has an efficient earthing connection which complies with the provisions of current regulations and the law;

there is easy access to the socket or the omnipolar circuit-breaker once the cooker has

been installed.

!do not use reducers, adapters or shunts as these could cause heating or burning.

Connection n° 2

Disposing of the plug.

!THIS APPLIANCE MUST BE EARTHED.

Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug:

!the wires in the mains lead are coloured in accordance with the following code:

Green & Yellow

-Earth

Blue

-Neutral

Brown

- L i v e

If the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

Connect Green & Yellow wire to terminal marked “E” or 6 or coloured Green or Green & Yellow.

Disposing of the appliance

When disposing of the appliance please remove the plug by cutting the mains cable as close as possible to the plug body and dispose of it as described above.

!The plug and socket must be easily accessible.

!The cable must be checked regularly and

replaced by authorised technicians only (see Assistance).

3

Page 3
Image 3
Indesit I. 89 K GP.A IX UK, I. 89 K GP.A UK manual Electrical connection, Green and Yellow Earth E

I. 89 K GP.A IX UK, I. 89 K GP.A UK specifications

The Indesit I.89 K GP.A UK and I.89 K GP.A IX UK represent the brand's commitment to user-friendly design combined with advanced features. These freestanding refrigerators are perfect for everyday use, catering to families and individuals seeking reliability and efficiency.

One of the standout features of both models is their impressive storage capacity. With a spacious interior, these appliances allow for organized storage of groceries, ensuring that food items are easily accessible. The adjustable shelves and compartments provide flexibility, enabling users to customize the space according to their needs.

Energy efficiency is another significant aspect of the Indesit I.89 K GP.A series. Designed with energy-saving technologies, these refrigerators help reduce electricity consumption, making them an environmentally friendly choice. They are equipped with A+ energy ratings, translating to lower utility costs and a lesser carbon footprint.

Both models also feature a solid No Frost technology, which eliminates the need for manual defrosting. This feature prevents ice build-up, ensuring consistent cooling performance and maintaining optimal conditions for food preservation. With No Frost, users can enjoy the convenience of hassle-free maintenance.

The design aesthetics of the Indesit I.89 K GP.A UK and I.89 K GP.A IX UK are equally impressive. The aesthetic appeal is highlighted by modern finishes—either in classic white or sleek stainless steel. These models seamlessly blend into contemporary kitchens, enhancing their visual appeal while providing high functionality.

Safety features, such as adjustable shelves that can accommodate taller items, and securely designed compartments, make these refrigerators user-friendly for every household member. Additionally, the efficient loudness of the cooling system ensures quiet operation, allowing for a peaceful home environment.

With their modern technologies, user-centric designs, and a commitment to sustainability, the Indesit I.89 K GP.A UK and I.89 K GP.A IX UK are excellent choices for anyone seeking a reliable refrigerator that meets all their storage needs while offering value for money. In summary, they epitomize functionality, efficiency, and style, making them standout options in the current market.