Indesit K3G2S/G specifications Adapting the oven

Models: K3G2S/G

1 12
Download 12 pages 17.67 Kb
Page 5
Image 5
Adapting the oven

￿The hob burners do not require primary air adjustment.

￿After adjusting the appliance so it may be used with a different type of gas, replace the old rating label with a new one that corresponds to the new type of gas (these labels are available from Authorised Technical Assistance Centres).

￿Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet hose in accordance with current national regulations relating to “regulators for channelled gas”.

Adapting the oven

Replacing the oven burner nozzle:

1. Remove the oven compartment.

2. Slide out the protection panel A

(see diagram).

A

3. Remove the oven burner

Vafter unscrewing the screws V

(see figure).

The whole operation will be made easier if the oven door is removed.

4. Unscrew the nozzle using a special nozzle socket spanner (see figure) or with a 7 mm socket spanner, and replace it with a new nozzle that is suited to the new type of gas (see Burner and nozzle specifications table).

Adjusting the gas oven burner’s minimum setting:

1.Light the burner (see Start-up and Use).

2.Turn the knob to the minimum position (MIN) after it has been in the maximum position (MAX) for approximately 10 minutes.

3.Remove the knob.

4.Tighten or loosen the adjustment screws on the outside of the thermostat pin (see figure) until the flame is small but steady.

￿ If the appliance is connected to liquid gas, the adjustment screw must be fastened as tightly as possible.

5. Turn the knob from the MAX position to the MIN

position quickly or open and shut the oven door, GB making sure that the burner is not extinguished.

Adapting the grill

Replacing the grill burner nozzle:

1. Remove the oven burner after loosening screw V (see

figure).

Manual background V

 

2. Unscrew the grill burner

 

nozzle using a special nozzle

 

socket spanner (see figure) or

 

preferably with a 7 mm socket

 

spanner, and replace it with a

 

new nozzle that is suited to the

I

new type of gas (see Burner

 

and nozzle specifications table).

 

￿Be careful of the spark plug wires and the thermocouple tubes.

￿The oven and grill burners do not require primary air adjustment.

￿After adjusting the appliance so it may be used with a different type of gas, replace the old rating label with a new one that corresponds to the new type of gas (these labels are available from Authorised Technical Assistance Centres).

￿Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet hose in accordance with current national regulations relating to “regulators for channelled gas”.

5

Page 5
Image 5
Indesit K3G2S/G specifications Adapting the oven