Indesit Installation, MODEL NUMBERS KD6G35, KDP60E, KDP60SE, Location, Technical Data

Models: KDP60SES KD6G35 KDP60E

1 20
Download 20 pages 17.86 Kb
Page 15
Image 15
Installation

Installation

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the back panel. This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. particular attention should be given to the relevant requirements regarding ventilation.

MODEL NUMBERS KD6G35, KDP60E, KDP60SE

Category II2H3+ (GB)

These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30) at 28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit that can be obtained free of charge, if you contact our Genuine Parts and Accessories department (see Key Contacts, back page).

GAS SAFETY (INSTALLATION & USE) REGULATIONS

It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law. In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution.

LOCATION

GB

The cooker may be located in a kitchen, kitchen/ diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3. When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal space below ground level, e.g. in a basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.

The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.

TECHNICAL DATA

Gas connection

Rp ½ (½" BSP female)

Pressure test point

Front left hotplate injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

4mm2 twin and earth

 

230/240V a.c. 50Hz.

 

 

G20 at 20mbar

G30 at 28-30mbar

 

 

G31 at 37mbar

 

 

 

 

 

 

 

 

 

 

 

Burner

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

 

 

 

 

 

 

 

HOTPLATE

3.05 kW

116

3.0 kW (220g/h)

86

 

Front Left

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

2.0 kW

103

2.0 kW (145g/h)

70

 

Rear Left and Rear Right

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

1.1 kW

79

1.0 kW (70g/h)

50

 

Front Right

 

 

 

 

 

 

 

 

 

 

 

 

GRILL

 

2.4 / 2.7 kW

 

 

 

 

 

 

 

 

MAIN OVEN

 

1.8 / 2.0 kW

 

 

 

 

 

 

 

 

TOP OVEN

 

1.7 / 1.9 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Page 15
Image 15
Indesit MODEL NUMBERS KD6G35, KDP60E, KDP60SE, Gas Safety Installation & Use Regulations, Location, Technical Data