InFocus IN5542C Command data, ① Controlling projector, Action byte0-1, Connection ID byte4-5

Models: IN5542 IN5544C IN5544 IN5542C

1 32
Download 32 pages 25.02 Kb
Page 16
Image 16
Command data

Daisy Chain Communication

Command data

Controlling projector

byte_0

byte_1

byte_2

byte_3

byte_4

byte_5

 

Action

 

Type

Setting Code

low

high

low

high

low

high

Action (byte_0-1)

Action

Classification

Content

1

Set

Change setting to desired value.

4

Increment

Increment setup value by 1.

5

Decrement

Decrement setup value by 1.

6

Execute

Run a command.

Note: For the Type and Setting Code, see the RS-232C communication/ Network command table (20).

Getting the projector’s status

byte_0

byte_1

byte_2

byte_3

byte_4

byte_5

 

Action

 

Type

Connection ID

low

high

low

high

low

high

Action (byte_0-1)

Action

Classification

Content

2Get Read projector internal setup value.

Connection ID (byte_4-5)

Connection ID

Content

0~255

This value is attached to the reply data.

Other commands

byte_0

 

byte_1

 

byte_2

 

byte_3

 

byte_4

byte_5

 

 

 

 

 

 

 

 

 

 

 

 

Action

 

Target Number

 

Connection ID

 

low

 

high

 

low

 

high

 

low

high

 

 

 

 

 

 

 

 

 

Support Command

 

 

Action

 

Target Number

 

Connection ID

 

 

 

 

 

 

 

 

Get the number of connected projectors

 

2

 

0

 

0~255

 

Set the communication Group

 

 

1

 

1~65535

 

0~255

 

identification and Communication ID

 

 

 

 

 

 

 

 

Get the communication Group

 

 

2

 

1~65535

 

0~255

 

identification and Communication ID

 

 

 

 

 

 

 

 

16