Daisy Chain Communication

Daisy Chain Communication

Transmitting side

1 2 3 4 5

6 7 8 9

Recieving side

1 2 3 4 5

6 7 8 9

CONTROL OUT port

RS-232C cable (Cross)

in Projector

- (1)

 

(1)

CD

 

 

 

RD (2)

(2)

RD

 

TD (3)

(3) TD

 

- (4)

 

(4)

DTR

 

GND (5)

 

 

(5) GND

 

 

 

 

- (6)

 

(6)

DSR

 

RTS (7)

(7)

RTS

 

CTS (8)

(8)

DTS

 

- (9)

 

(9)

RI

1.Communications setting

 

 

 

CONTROL IN port in Projector

Set the same communication settings (selecting from options below) on the CONTROL terminal for transmitting and receiving side connected with a RS-232C cable.

Baud rate: 4800 / 9600 / 19200 / 38400 bps Parity NONE / ODD / EVEN

Data bit: 8 bit (fixed)

Start bit: 1 bit (fixed)

Stop bit: 1 bit (fixed)

2.Commands available only for daisy chain communication

The projector supports the following commands only for daisy chain.

(1)Control the projector (Set/Increment/Decrement/Execute)

(2)Get the projector’s status (Get)

(3)Get the number of connected projectors

(4)Set the communication Group identification and Communication ID.

(5)Get the communication Group identification and Communication ID.

3.Command format

Protocol

Consist of header data (7 bytes) + command data (6 bytes)

Header

BE + EF + Packet_Type + 06 + Group + ID + Checksum

Data chart

Support Command

Packet_Type

Group

ID

 

 

 

 

Control the projector

‘83H’

0~16

0~64

Get the projector’s status

‘83H’

1~16

1~64

Get the number of connected projectors

‘84H’

0

0

Set the communication Group

‘85H’

1~16

1~64

identification and Communication ID

 

 

 

Get the communication Group

‘86H’

0

0

identification and Communication ID

 

 

 

14

Page 14
Image 14
InFocus IN5544C, IN5542C Daisy Chain Communication, Commands available only for daisy chain communication, Command format