35
1Turn the projector off and unplug the power cord.
2Wait 60 minutes to allow the projector to cool thoroughly.
3Remove the lamp doors by loosening 2 captive screws on each lamp door and
pulling the doors straight off being careful not to damage the ground wires
connecting the doors to the projector. Note: Do not remove the ground wires.
4Loosen the 3 captive shoulder screws (marked by arrows) that attach the first
lamp module to the projector. Carefully remove the lamp module. Do the same
for the second lamp module. Dispose of the lamps in an environmentally
proper manner in accordance with local disposal laws.
5Carefully align and insert the new lamp modules and tighten the screws.
6Replace the lamp doors and secure the screws.
7Plug in the power cord, turn on the power switch and press the Power button
to turn the projector back on. Note: Connection to a circuit with a minimum of
20A capacity is recommended.
8To reset the lamp hour timer, use the RS232 commands, LMR (Lamp 1) and LDR
(Lamp 2). See “Control commands” on page 47 for more informatio n.
Turn off and unplug projector
Wait 60
minutes
(1) (2)

(3) (4)
(5) (6)
Lamp 2
Lamp 1