OPERAT

OR’S MANUAL

635043

RELEASED: 9-8-83
REVISED: 7-7-00
(REV.
B)
ARO STOPR
OPERATION,
INST
ALLA
TION & MAINTENANCE

635043

PUMP SAVER CONTROL VALVE - 3/4” PIPE SIZE
READ THIS MANUAL CAREFULL
Y BEFORE INST
ALLING,
OPERA
TING OR SER
VICING THIS EQUIPMENT
.
It
is the responsibility of the employer to place this information in the hands of the operator
. Keep for future reference.
GENERAL
DESCRIPTION
This device is to terminate operation of an 8" to 12" reciprocating type
air motor in the event of a ruptured outlet hose or the pump runs out of
media. For compressed air use only.
Operating Pressure Range 30 Ć 120 p.s.i. (2.1 Ć 8.3 bar)...
Temperature Range 0_to 180_F (Ć18_to 82_C).........
OPERATION
The AROĆSTOP control valve senses an increased volume of air to the
pump, beyond the preadjusted setting, and shuts off the air supply to
the pump. The runaway" condition may be caused by any of the followĆ
ing: 1.) depleted pump material, 2.) a ruptured line on the outlet of the
pump, 3.) excessive cavitation in the material supply.
INSTALLATION
The AROĆSTOP valve should be installed in a filtered and regulated air
line. The Filter & Regulator should be no smaller than an Aro HeavyĆ
Duty series. Upstream plumbing from the AROĆSTOP should be 3/4"
minimum. The 3/4" swivel furnished with the AROĆSTOP is to be
installed on the inlet of the AROĆSTOP to facilitate easy adjustment.
Install the outlet of the AROĆSTOP on the inlet of pump motor. InstallaĆ
tion of AROĆSTOP as illustrated is recommended. Use one AROĆSTOP
for each pump. See typical installation photo.
E2000 D PRINTED IN U.S.A.
&
(419) 636-4242
D
F
AX (419) 633-1674
INGERSOLL-RAND COMPANY
P.O. BOX 151 DONE ARO CENTER DBRYAN, OHIO 43506Ć0151