INSTALLATION

The 65053X-X Chop-Check Dispensing System comes completely assembled. Remove unit from crate and place on a level surface. Install material hose and dispensing device as required.

When the following instructions are observed, heavy paste materials can be pumped directly from their original 5 gallon drum without air inF

clusion, or excessive waste. The follower plate creates an air tight seal as well as clean-wiping action in its progressive downward movement into the drum.

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS ￿ INITIAL SETUP PROCEDURE

WARNING STAND CLEAR￿ Wh-n raising or low-ring th-

lift￿ Read the warning on page 2 of 651615 Single Post Lift/Ram

2Operator's Manual.

AIR CONTROLS

 

 

 

CONTROL

LIFT￿RAM

 

LEVER

PRESSURE

 

 

REGULATOR

 

 

LIFT￿RAM

 

 

PRESSURE

 

AIR

GAUGE

 

 

INLET

 

 

PUMP

 

 

FILTER￿REGULATOR

 

 

OFF

ON

 

 

 

FOLLOWER PLATE

 

AIR SUPPLY VALVE

 

FIGURE 2

 

 

TO RAISE LIFT￿ ￿THE FIRST TIME￿:

1.Take note of the pump/drum clearance above. Be certain the lift is clear of any objects above. Also refer to OPERATING AND SAFEF TY PRECAUTIONS found on page 2 of 651615 Single Post Lift/ Ram Operator's Manual.

2.Connect the air supply (160 PSI MAX) to the air inlet. Adjust (Turn Lift/ Ram Pressure Regulator Knob Clockwise) air pressure on lift/ram presF sure regulator to 20 P.S.I. (1.2 Bar)

3.Shift the control valve lever to the ``UP'' position.

4.Raise the lift high enough to clear the height of the drum. Stop the lift upward travel by moving the control valve lever to the (center) ``NEUTRAL'' position.

REFER TO PAGE 3:

1.Once lift assembly and pump are in the ``UP" position, place and center an opened 5 gallon drum of material on the lift/ram base. Use the stops on the base to center 5 gallon drum. Tighten thumb screw to secure drum.

2.Lubricate lower follower wiper plate seal with any type grease. (siliF cone, vaseline, gear, etc.) This ensures a smooth fit into the pail as well as prevents curing type compounds from bonding to seal.

3.Check vent plug on follower plate to be sure it easily threads in and out. It is recommended to lubricate the threads of the plug to help prevent possible set up of compound at this point. S-- 65184X￿X Op-rator's Manual￿

TO LOWER LIFT:

WARNING PINCH HAZARD￿ Follow-r can d-sc-nd quickly

causing injury￿ K--p hands cl-ar wh-n aligning with containA -r￿ Read the warning on page 2 of 651615 Single Post Lift/Ram Operator's Manual..

NOTE: B- c-rtain th- Follow-r Plat- v-nt plug has b--n r-mov-d so that the air trapped between the follower and the material is allowed to escape from this vent. Captured air between the follower plate and drum will escape.

NOTE: The lift may hesitate momentarily before starting downward, the air pressure inside the post air chamber must decrease before it will begin to descend.

1.Shift the control valve lever to the ``DOWN'' position and proceed to lower the pump.

2.Replace the vent plug once the material begins to ooze from the vent opening.

3.The unit is now ready for operation. Adjust (Turn pump regulator Clockwise) air pressure on pump Filter/Regulator until pump beF gins to cycle.

4.Trigger gun to prime pump with material.

TO RAISE LIFT￿ ￿NORMAL OPERATION￿:

1.Adjust the Follower Plate Air Valve pressure up to approximately 8 psig. DO NO OVERPRESSURIZE THE DRUM to avoid damage. NOTE: Air from this valve will only pass when the Control Lever is in the ``UP'' position.

2.Shift the control valve lever to the ``UP'' position.

3.Raise the lift high enough to clear the height of the drum. Stop the lift upward travel by moving the control valve lever to the (center) ``NEUTRAL'' position.

TO CHANGE DRUM:

NOTE: The Control Lever should be in the ``NEUTRAL'' position.

1.Unsrew thumb screw and remove old 5 gallon drum.

2.Place and center. a new drum into position. Remove cover. TightF en thumb screw.

PAGE 2 OF 4

Page 2
Image 2