Broilers wired for
All required broiler wiring diagrams are packaged separately in a clear plastic ziplock bag and shipped with the broiler.
ELECTRICAL DATA CHART
STANDARD VOLTAGES - 208 VOLTS OR 240 VOLTS 60 Hz 1 PHASE - 480 VOLTS 60 Hz 3 PHASE ONLY
|
|
|
|
|
|
| NOMINAL AMPS PER LINE |
|
|
| |||||||||||||
|
| TOTAL | LOADING |
|
|
|
|
|
|
|
|
|
|
| |||||||||
| VOLTS | KW | KW PER PHASE | 208V | 240V |
| 208V |
|
|
| 240V |
|
|
| 480V |
| |||||||
MODEL DESCRIPTION | 60 Hz | CON. |
|
|
|
| X |
| Y | Z |
| X |
| Y | Z |
| X |
| Y | Z | |||
VB2S Broiler w/Storage Base | 12.0 | 3 |
| 6 |
| 3 | 58 | 50 | 25 | 37 | 37 | 22 | 32 | 32 | 16 | 11 | 16 | ||||||
VB21 Broiler w/Oven | 18.7 | 6 |
| 6 |
| 6.7 | 90 | 78 | 53 | 50 | 53 | 45 | 43 | 45 | 23 | 21.5 | 23 | ||||||
VB22S Dbl.Broiler w/Storage | 24.0 | 9 |
| 9 |
| 6 | 115 | 100 | 62 | 74 | 62 | 54 | 65 | 54 | 32 | 27 | 27 | ||||||
VB221 Dbl.Broiler w/Oven | 30.7 | 12 |
| 10 |
| 8.7 | 148 | 128 | 86 | 91 | 78 | 74 | 79 | 67 | 40 | 37 | 34 | ||||||
STANDARD VOLTAGES - 208 VOLTS OR 240 VOLTS 60 Hz 1 PHASE OR 3 PHASE - 480 VOLTS 60 Hz 3 PHASE ONLY |
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| NOMINAL AMPS PER LINE |
|
|
| |||||||||||||
|
| TOTAL | LOADING |
|
|
|
|
|
|
|
|
|
|
| |||||||||
| VOLTS | KW | KW PER PHASE | 208V | 240V |
| 208V |
|
|
| 240V |
|
|
| 480V |
| |||||||
MODEL DESCRIPTION | 60 Hz | CON. |
|
|
|
| X |
| Y | Z |
| X |
| Y | Z |
| X |
| Y | Z | |||
VTMB2 Single Broiler | 480 | 12.0 | 3 |
| 3 |
| 6 | — | — | — | — | — | — | — | — | 16 | 11 | 16 | |||||
VTMB2 Single Broiler | 12.0 | 3 |
| 6 |
| 3 | 58 | 50 | 25 |
| 37 | 37 |
| 22 |
| 32 | 32 |
| — |
| — | — | |
VTMB22 Double Broiler | 480 | 24.0 | 9 |
| 6 |
| 9 | — | — | — | — | — | — | — | — | 32 | 27 | 27 | |||||
VTMB22 Double Broiler | 24.0 | 9 |
| 9 |
| 6 | 115 | 100 | 62 |
| 74 | 62 |
| 54 |
| 65 | 54 |
| — |
| — | — |
BROILERS WITH CONVECTION OVENS
”N/A” BROILERS NOT AVAILABLE IN 480V 1 PHASE
|
|
|
|
| NOMINAL AMPS PER LINE WIRE |
|
|
| |||||||||||||
|
| KW PER PHASE | KW PER PHASE |
|
|
|
| 3 PHASE |
|
|
|
| 1 PHASE | ||||||||
| TOTAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 208 & 240V |
| 480V |
|
| 208V |
|
|
| 240V |
|
| 480V |
| 208V | 240V | 480V | ||||
| KW |
|
|
|
|
|
|
|
|
| |||||||||||
MODEL | CONN. | X | Y | Z | X |
| Y |
| Z | X | Y | Z | XYZ | XYZ | XYZ | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VB21C | 19.0 | 4.2 | 7.2 | 7.6 | 7.2 | 7.2 | 4.6 | 65 | 53 | 54 | 43 |
| 41 |
| 53 | 21 | 26 | 21 | 91 | 79 | 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VB221C | 31.0 | 10.2 | 10.2 | 10.6 | 7.2 | 13.2 | 10.6 | 87 | 85 | 87 | 75 |
| 74 |
| 75 | 32 | 337 | 43 | 149 | 129 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 5 –