ELECTRICAL TESTS

ELECTRICAL TESTS

Turn each switch from LOW through HIGH and verify that it controls the heating elements correctly.

Free Standing Models - 208V & 240V

Left switch controls front element, LOW-HIGH

Right switch controls rear element, LOW-HIGH

Free Standing Models - 480V

Left switch controls two front elements

Right switch controls two rear elements:

LOW = 2 elements on LOW

MED = 1 element on HIGH and 1 element OFF

HIGH = 2 elements on HIGH

Model VB73 - 208V & 240V

Top switch controls left element, LOW-HIGH

Bottom switch controls right element, LOW-HIGH

Model VB73 - 480V

One switch controls 2 elements:

LOW = left and right elements on LOW

MED = left element OFF, right element on HIGH

HIGH = left and right elements on HIGH

LEVELING

Using a carpenter's level placed on top of the broiler, adjust the feet of the broiler so that the broiler is level front-to-back and side-to-side.