PUMP OPTION DESCRIPTION CHART
650944 X X X -B
PACKING MATERIAL
SPRING ARRANGEMENT
PLUNGER TYPE
PACKING MATERIAL (packings are upper and lower unless noted)
3Glass filled PTFE C
G
PUHMW
R PTFE /
SPRING ARRANGEMENT
4Multiple wave spring with 316 stainless steel balls
7 Multiple wave spring with 440 stainless steel balls
PLUNGER TYPE
3Hardened stainless steel with hard chrome plating B Hardened stainless steel with ceramic coating
GENERAL DESCRIPTION
WARNING HAZARDOUS PRESSURE. Do not exceed maxi- mum operating pressure of 3960 p.s.i. (273.1 bar) at 1200 p.s.i. (82.8 bar) inlet hydraulic pressure.
PUMP RATIO X | = | MAXIMUM PUMP |
INLET PRESSURE TO PUMP MOTOR | FLUID PRESSURE |
Pump ratio is an expression of the relationship between the pump motor area and the lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied to the motor of a 5:1 ratio pump it will develop a maximum of 750 p.s.i. (52 bar) fluid pres- sure (at no flow) - as the fluid control is opened, the flow rate will increase as the motor cycle rate increases to keep up with the demand.
WARNING Refer to general information sheet for additional safety precautions and important information.
• The
• The motor is connected to the lower pump end by a spacer section. This allows for lubrication of the upper packing gland and prevents motor contamination because of normal wear and eventual leakage through the material packing gland. Be sure the solvent cup is ade- quately filled with lubricant to protect the upper packings and insure longest service life.
TROUBLE SHOOTING
Pump problems can occur in either the hydraulic motor section or the lower pump end section, use these basic guidelines to help determine which section is affected.
If the pump will not cycle.
•Be certain to first check for
•Refer to the motor manual for trouble shooting if the pump does not
cycle and / or hydraulic fluid leaks from the hydraulic motor. If the pump cycles but does not deliver material.
•Refer to the lower pump end manual for further trouble shooting.
PUMP CONNECTION - UPPER / LOWER
NOTE: All threads are right hand.
1.Lay the pump assembly on a workbench.
2.Remove the three screws and washers from the three spacer rods (see figure 1).
3.Pull the hydraulic motor from the lower pump end until motor piston rod is in the
tion.
4.Using
PUMP CONNECTOR DETAIL
Pump Motor Piston Rod
Retaining Ring 91547
Sleeve 91546
Connector 91644 (2)
Lower Pump Piston Rod
Figure 2
REASSEMBLY
1.Align the pump motor with the lower pump end.
2.Install the two connectors and retain with the sleeve, slide the retain- ing ring back into position.
3.Reinstall the spacer rods to the pump motor.
4.Bring the motor and lower pump together and retain with the three screws and washers.
PN
Page 2 of 2 |