SPECIFICATIONS
Material Inlet . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 - 18 N.P.S.M. Air Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8 - 27 N.P.T.F. - 1 Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2” (50.8 mm) Length (without nozzle) . . . . . . . . . . . . . . .
@ 2000 p.s.i. (138 bar) Fluid Pressure . 50 p.s.i. (3.4 bar)
DESCRIPTION
The following model guns permit spraying or extruding of material continuously or intermittently by using spring re- turn. See chart below for characteristics of each model.
These unit are identical expect spray guns include a spray guard which retains the
Model | Material | Includes | Tips |
|
|
|
|
Heavy Materials |
| ||
|
|
|
|
Light Fluids | 66504 Cap |
OPERATION
Turn air to “ON” position at supply source. Air must be regu- lated at 60 p.s.i. (4 bar) to maintain proper performance.
STROKE ADJUSTMENT
For maximum fluid flow and tip and needle life;
1.Turn knurled adjusting screw (23) counterclockwise until contact is lost between it and (15) nut.
2.Turn adjusting screw clockwise until contact is again made with the (15) nut.
3.Back out adjusting screw approximately 1/4 turn.
4.Lock (23) adjusting screw in place by tightening (24) nut.
MAINTENANCE
To maintain reliable performance, the gun should be flushed out with a compatible solvent immediately following each spray or extrusion period. This will decrease the chance of material
INGERSOLL RAND COMPANY LTD
P.O. BOX 151 y ONE ARO CENTER y BRYAN, OHIO
(800) | © 2007 | CCN 81379786 |
AUTOMATIC EXTRUSION GUNS
(Extrusion nozzle and retaining nut must be ordered separately.) |
2” |
31/32” |
Figure 1 |
AUTOMATIC AIRLESS SPRAY GUNS
Figure 2
OPERATING AND SAFETY PRECAUTIONS
WARNING HIGH PRESSURE DEVICE. Improper usage of equipment could result in serious injury. The pos- sibility of injection into the flesh is a potential hazard. Never allow any part of the human body to come in front of or in direct contact with the material outlet.
WARNING AN INJECTION INJURY CAN BE SERIOUS. If injection should occur, contact a qualified physician for immediate treatment of such injuries.
WARNING DO NOT EXCEED MAXIMUM WORKING PRES- SURE OF 5000 P.S.I. (345 BAR).
WARNING ALWAYS DISCONNECT THE MATERIAL LINE AND THE AIR INLET BEFORE SERVICING THIS UNIT TO REDUCE THE CHANCE OF ACCIDENTAL DISCHARGE.