OPERATOR’S MANUAL |
|
|
|
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
STAINLESS STEEL FLUID HEATER
RELEASED:
REVISED:
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
FLUID HEATER DATA
Models . . . . . . . . . . . . . . . . . . . . . . . . . 651747XB Wetted Parts Material . . . . . . . . . . . . . . Stainless Steel
Volts AC 6517471B . . . . . . . . . . . . 120 6517472B . . . . . . . . . . . . 230 / 240 6517473B . . . . . . . . . . . . 415 / 440
Amperes 6517471B . . . . . . . . . . . . 16.6 6517472B . . . . . . . . . . . . 8.3 6517473B . . . . . . . . . . . . 4.5
Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . ± 31/2_ F (1.9_ C) Temperature Rise Above Ambient . . . . . 100_ F (38_ C) Recovery Rate per Hour . . . . . . . . . . . . 15 gallons (56.8 liters) Maximum Working Pressure . . . . . . . . . 5000 p.s.i. (35 MPa) Maximum Temperature Range . . . . . . . 60 250_ F (16 121_ C) Surface Temperature Code . . . . . . . . . . T3 (392_ F / 200 _ C) Fluid Passage Diameter . . . . . . . . . . . . 0.370" (9.4 mm)
Fluid Passage Length . . . . . . . . . . . . . . 91.7" (232.9 cm) Fluid Passage Volume . . . . . . . . . . . . . . 9.86 in.3 (0.162 lit.) Inlet / Outlet Port Size (female) . . . . . . . 1/2 14 N.P.T.F. 1 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 18 lbs (8.2 kg)
GENERAL DESCRIPTION
The Aro stainless steel fluid heater models are wired for 120, 230 / 240 and 415 / 440 volt AC applications. The heating element is a 2000 watt cartridge type and is thermostatically controlled. The wiring, heating element and thermostat are protected by a preset heat limiter.
The thermostat is adjustable up to 250_ F (121_ C). The heater is off when the thermostat knob is turned counterclockwise as far as pos sible. The heater will not switch on until the knob is rotated to at least ambient room temperature.
Fluid heaters have been tested in a water solution. Some of this fluid may be left within the heater, therefore flush out this fluid with a solvent compatible with the material to be pumped.
•This unit utilizes an explosionproof electrical section and internally spiraling material section. The material enters the base under line pressure from the pump and is heated and delivered thru to the ma terial outlet at the top.
•This unit is CSA certified for Class I, Division 1, Group D, Hazard ous Locations, Temperature Code (identification number) T3.
•Two or more paint heaters may be coupled together by plumbing the material outlet of the first heater to the material inlet of the next, etc. However, the distance of piping run between the units should be limited to no more than three feet (see figure 4, page 4).
TYPICAL INSTALLATION
The heater inlet and outlet should be plumbed (up flow) as shown (see figure 4, page 4), to minimize chances of trapped air inside the heater. If the inlet and outlet are reversed (down flow), the temperature rise will be different.
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 435060151
& (419)
DIMENSIONAL DATA
651747/X/B FLUID HEATER |
| |
| 7/1/2" |
|
| (190.5 mm) | |
7/8" (22.2 mm) |
|
|
| 4/3/4" | 4/3/16" |
1/2 / 14 N.P.T.F. | (120.7 mm) | (105.6 mm) |
Mounting holes (hidden) |
|
|
Thermometer - Do not over/ |
|
|
tighten. For orientation only. |
|
|
1/2 / 14 N.P.T.F. (Outlet) |
| 16/1/16" |
|
| (408.0 mm) |
| 3/3/4" |
|
| (95.3 mm) |
|
8/13/16" |
|
|
(223.8 mm) |
|
|
R | 1/2 / 14 N.P.T.F. (Inlet) | |
|
| |
FIGURE 1 |
|
OPERATING PRECAUTIONS
•Heed all warnings.
WARNING Do not exceed 5000 p.s.i. (35 MPa) maximum.
WARNING HIGH PRESSURE DEVICE. Improper usage of this equipment could result in serious injury. The possibility of injection into the flesh is a potential hazard. Never allow any part of the human body to come in front of, or in direct contact with, the material outlet. An injection injury can be serious. If injection should occur, contact a qualified physician for imme/ diate treatment.
CAUTION Electrical supply power to the heater must be off during flushing operation.
CAUTION Use only genuine Aro replacement parts to as/ sure compatible pressure rating and longest service life.