OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
| EXCESSIVE AIR PRESSURE | HAZARDOUS MATERIALS |
|
| WARNING | HAZARDOUS MATERIALS. Can cause serious in- | |||
|
|
| jury or property damage. Do not attempt to return a pump to the | ||||||
| STATIC SPARK | HAZARDOUS PRESSURE |
|
| |||||
|
|
|
|
|
| factory or service center that contains hazardous material. | |||
|
|
|
|
|
| Safe handling practices must comply with local and national | |||
|
|
|
|
| |||||
| WARNING | EXCESSIVE AIR PRESSURE. Can cause person- |
| laws and safety code requirements. | |||||
| al injury, pump damage or property damage. | S Obtain Material Safety Data Sheets on all materials from the | |||||||
|
| supplier for proper handling instructions. | |||||||
S Do not exceed the maximum inlet air pressure as stated on the |
| ||||||||
| pump model plate. |
|
|
| WARNING | EXPLOSION HAZARD. Models containing alumi- | |||
S Be sure material hoses and other components are able to with- |
| num wetted parts cannot be used with | |||||||
| stand fluid pressures developed by this pump. Check all hoses |
| thylene Chloride or other Halogenated Hydrocarbon solvents | ||||||
| for damage or wear. Be certain dispensing device is clean and |
| which may react and explode. | ||||||
| in proper working condition. |
|
| S Check pump motor section, fluid caps, manifolds and all | |||||
| WARNING | STATIC SPARK. Can cause explosion resulting in |
| wetted parts to assure compatibility before using with solvents | |||||
| severe injury or death. Ground pump and pumping system. |
| of this type. |
|
| ||||
S Sparks can ignite flammable material and vapors. |
| CAUTION |
| Verify the chemical compatibility of the pump | |||||
S | The pumping system and object being sprayed must be |
| wetted parts and the substance being pumped, flushed or re- | ||||||
| grounded when it is pumping, flushing, recirculating or spray- |
| circulated. Chemical compatibility may change with tempera- | ||||||
| ing flammable materials such as paints, solvents, lacquers, |
| ture and concentration of the chemical(s) within the | ||||||
| etc. or used in a location where surrounding atmosphere is |
| substances being pumped, flushed or circulated. For specific | ||||||
| conducive to spontaneous combustion. Ground the dispens- |
| fluid compatibility, consult the chemical manufacturer. | ||||||
| ing valve or device, containers, hoses and any object to which |
| CAUTION |
| Maximum temperatures are based on mechani- | ||||
| material is being pumped. |
|
|
| cal stress only. Certain chemicals will significantly reduce | ||||
S Use the pump grounding screw terminal provided. Use ARO |
| ||||||||
| maximum safe operating temperature. Consult the chemical | ||||||||
| part no. |
| |||||||
|
| manufacturer for chemical compatibility and temperature lim- | |||||||
| (12 ga. min.) to a good earth ground source. |
| |||||||
|
| its. Refer to PUMP DATA on page 1 of this manual. | |||||||
S Secure pump, connections and all contact points to avoid |
| ||||||||
| CAUTION |
| Be certain all operators of this equipment have | ||||||
| vibration and generation of contact or static spark. |
|
| ||||||
|
| been trained for safe working practices, understand it’s limita- | |||||||
S Consult local building codes and electrical codes for specific |
| ||||||||
| tions, and wear safety goggles / equipment when required. | ||||||||
| grounding requirements. |
|
|
| |||||
|
|
|
| CAUTION | Do not use the pump for the structural support of | ||||
S After grounding, periodically verify continuity of electrical path |
| ||||||||
| the piping system. Be certain the system components are | ||||||||
| to ground. Test with an ohmmeter from each component (e.g., |
| |||||||
| hoses, pump, clamps, container, spray gun, etc.) to ground to |
| properly supported to prevent stress on the pump parts. | ||||||
| insure continuity. Ohmmeter should show 0.1 ohms or less. | S Suction and discharge connections should be flexible connec- | |||||||
S Submerse the outlet hose end, dispensing valve or device in |
| tions (such as hose), not rigid piped, and should be compatible | |||||||
| the material being dispensed if possible. (Avoid free streaming |
| with the substance being pumped. | ||||||
| of material being dispensed.) |
|
|
| CAUTION |
| Prevent unnecessary damage to the pump. Do | ||
S Use hoses incorporating a static wire. |
|
|
| not allow pump to operate when out of material for long periods | |||||
S | Use proper ventilation. |
|
|
| of time. |
|
| ||
S Keep inflammables away from heat, open flames and sparks. | S Disconnect air line from pump when system sits idle for long | ||||||||
S Keep containers closed when not in use. |
| periods of time. | |||||||
| WARNING | Pump exhaust may contain contaminants. Can |
| CAUTION | Use only genuine ARO replacement parts to as- | ||||
|
|
|
|
|
|
| |||
| cause severe injury. Pipe exhaust away from work area and per- |
| sure compatible pressure rating and longest service life. | ||||||
| sonnel. |
|
|
| NOTICE |
| Replacement warning labels are available upon | ||
S In the event of a diaphragm rupture material can be forced out |
| request: ‘‘Static Spark pn \ | |||||||
| of the air exhaust muffler. |
|
|
| |||||
|
|
| 93122." |
|
|
| |||
S Pipe the exhaust to a safe remote location when pumping haz- |
|
|
| ||||||
|
|
|
|
| |||||
| ardous or inflammable materials. |
|
|
|
|
| = Hazards or unsafe practices which could |
| |
S Use a grounded 3/8" minimum i.d. hose between the pump and |
| WARNING |
| ||||||
| the muffler. |
|
|
|
|
| result in severe personal injury, death or |
| |
|
|
|
|
|
| substantial property damage. |
| ||
|
|
|
|
|
|
|
|
| |
| WARNING | HAZARDOUS PRESSURE. Can result in serious |
|
|
| ||||
|
|
|
| = Hazards or unsafe practices which could |
| ||||
|
|
|
| CAUTION |
| ||||
| injury or property damage. Do not service or clean pump, | ||||||||
| hoses or dispensing valve while the system is pressurized. |
|
|
| result in minor personal injury, product or |
| |||
|
|
|
| property damage. |
| ||||
S Disconnect air supply line and relieve pressure from the sys- |
|
|
|
| |||||
|
|
|
|
| |||||
| tem by opening dispensing valve or device and / or carefully |
| NOTICE | = Important installation, operation or |
| ||||
| and slowly loosening and removing outlet hose or piping from |
|
|
| maintenance information. |
| |||
| pump. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Page 2 of 8 |