TROUBLE SHOOTING

Product discharged from exhaust outlet.

SCheck for diaphragm rupture.

SCheck tightness of (14) diaphragm screw.

Air bubbles in product discharge.

SCheck connections of suction plumbing.

SCheck

SCheck tightness of (14) diaphragm screw.

Low output volume, erratic flow, or no flow.

SCheck air supply.

SCheck for plugged outlet hose.

SCheck for kinked (restrictive) outlet material hose.

SCheck for kinked (restrictive) or collapsed inlet material hose.

SCheck for pump cavitation − suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped. Suction hose must be a non-col- lapsing type, capable of pulling a high vacuum.

SCheck all joints on the inlet manifolds and suction connections. These must be air tight.

SInspect the pump for solid objects lodged in the diaphragm chamber or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

1- 11-1/2 N.P.T.F. - 1 (66610X, 66611X) Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)

8" (203 mm)

8-9/16"

(217.5 mm)

Outlet

12-1/2"

11-9/16"

 

 

(318 mm)

(294 mm)

 

Air Inlet

 

 

 

 

 

 

1/4 - 18 N.P.T.F. - 1

 

 

 

6-1/2"

 

 

Inlet

(165 mm)

 

 

 

6-1/4"(159 mm)

1-1/4" (32 mm)

4" (102 mm)

 

7-5/16" (186 mm)

 

13/32" Slot (10 mm)

1- 11-1/2 N.P.T.F. - 1 (66610X, 66611X) Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)

Figure 5

 

PN 97999-100

 

 