TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.

Check tightness of diaphragm nut.

Air bubbles in product discharge.

Check connections of suction plumbing.

Check “O” rings between intake manifold and fluid caps.

Check tightness of diaphragm nut.

Low output volume, erratic flow, or no flow.

Check air supply.

Check for plugged outlet hose.

Check for kinked (restrictive) outlet material hose.

Check for kinked (restrictive) or collapsed inlet material hose.

Check for pump cavitation − suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped. Suction hose must be a non-collapsing type, capable of pulling a high vacuum.

Check all joints on the inlet manifolds and suction con- nections. These must be air tight.

Inspect the pump for solid objects lodged in the dia- phragm chamber or the seat area.

DIMENSIONAL DATA

Dimensions shown are for reference only,they are shown in inches and millimeters (mm).

 

 

(6661XJ-X, 6661XK-X, 6661XS-X) 1 - 11-1/2 N.P.T.F. - 1

Figure 6

K

E

 

(6661XL-X, 6661XN-X, 6661XT-X) 1 - 11 BS Rp

 

 

 

 

Outlet

N Bolt Circle

 

 

 

K

A

 

 

 

 

 

Outlet

 

 

 

 

B

 

F

F

 

 

 

 

 

 

 

 

D

Inlet

 

 

 

 

 

 

M

Inlet

 

 

 

 

G

L

 

J

 

 

 

 

 

H

 

 

C

(6661X3-X, 6661X4-X, 6661XP-X) 1” A.N.S.I. Flange

 

May be tapped for 1” pipe.

 

 

 

(6661XF-X, 6661XG-X, 6661XR-X) 1” A.N.S.I. / DIN Flange

 

 

1/4 - 18 N.P.T. Air Inlet

DIMENSIONS 6661XJ-X

6661XL-X

6661X3-X6661XS-X

6661XP-X 6661X4-X 6661XT-X

6661XK-X 6661XF-X

6661XN-X 6661XR-X 6661XG-X

A

12-21/32” (321 mm)

12-15/32”

(316 mm) 13-5/32” (334 mm)

13-1/32”

(331 mm)

13-5/32” (334 mm)

13-1/32 (331 mm)

B

13-25/32” (349 mm)

13-19/32”

(345 mm) 13-25/32” (350 mm) 13-19/32” (345 mm) 13-25/32” (350 mm) 13-19/32” (345 mm)

C

10-1/16” (255 mm)

9-15/16” (252 mm)

10-1/16” (255 mm)

9-15/16”

(252 mm)

10-1/16” (255 mm)

9-15/16”

(252 mm)

D

2-3/8”

(60 mm)

2-11/32”

(59 mm)

2-11/32” (59 mm)

2-5/16”

(59 mm)

2-11/32” (59 mm)

2-5/16”

(59 mm)

E

8-1/16”

(204 mm)

7-15/16” (201 mm)

8-1/16” (204 mm)

7-15/16”

(201 mm)

8-1/16” (204 mm)

7-15/16”

(201 mm)

F

16” (406 mm)

15-25/32”

(400 mm) 14-13/16” (376 mm)

14-5/8” (371 mm)

16” (406 mm) 15-25/32” (401 mm)

G

5-1/32”

(128 mm)

4-31/32” (126 mm)

5-1/32” (128 mm)

4-31/32”

(126 mm)

5-1/32” (128 mm)

4-31/32”

(126 mm)

H

6-9/32”

(160 mm)

6-7/32” (157 mm)

6-9/32” (160 mm)

6-7/32” (157 mm)

6-9/32” (160 mm)

6-7/32” (157 mm)

J

7/16” (11 mm)

7/16” (11 mm)

7/16” (11 mm)

7/16” (11 mm)

7/16” (11 mm)

7/16” (11 mm)

K

15/16” (23 mm)

29/32” (23 mm)

2” (51 mm)

1-25/32” (50 mm)

1-1/32” (26 mm)

1” (25 mm)

L

2-9/32” (57 mm)

2-1/4” (56 mm)

 

 

 

 

 

 

M

1/2” (13 mm)

1/2” (13 mm)

1/2” (13 mm)

1/2” (13 mm)

1/2” (13 mm)

1/2” (13 mm)

N

3.140” (80 mm)

3.097” (79 mm)

 

 

 

3.140” (80 mm)

3.097” (79 mm)

 

PN 97999-20