Ingersoll-Rand 72643D manual 3” AIR MOTOR, 50 1 RATIO, 2 1/4” STROKE, Service Kits, Pump Data

Models: 72643D 72654XD

1 4
Download 4 pages 52.01 Kb
Page 1
Image 1
OPERATOR’S MANUAL

OPERATOR’S MANUAL

 

72643–D

INCLUDING:￿SERVICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING

 

72654–X–D

ALSO INCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2 GENERALIN!

 

FORMATION SHEET.

BASIC PUMP

RELEASED: 6–21–95

(REV. A) IPP/PSE

3” AIR MOTOR

 

 

 

50:1 RATIO

72643–D

72654–X–D

2 1/4” STROKE

35 LB DRUM

400 LB DRUM

 

 

 

 

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

SERVICE KITS

Use only genuine AROR replacement parts to assure compatible pressure rating and longest service life.

637066-B for repair of Air Motor section.

60520 for repair of Lower Pump section.

GENERAL DESCRIPTION

This model is designed for delivery of heavy viscosity fluids such as chassis lubrication fluids. Material dispensing accessories and supply lines and fittings must be capable of withstanding pressures developed by pump.

The ARO 50:1 ratio basic pump assembly consists of a 3" air motor and lower pump end.

RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID PRESSURE.

The 50:1 ratio is an expression of the relationship between the air motor area and the lower pump end area. When 150 p.s.i. (10 bar) air pressure is supplied to the air motor, the lower pump end will develop a maximum of 7,500 p.s.i. (517 bar) fluid pressure (at no flow) - as the fluid control is opened, the flow rate will increase as the air motor cycle rate increases to keep up with the demand.

PUMP DATA

 

66410

 

 

 

Air Motor

 

 

1/2 NPT

 

 

Mat’l Outlet

 

``A"

 

 

 

 

Model No.

``A"

``B"

 

72643-D

27.3"

19.1"

 

(693.4 mm)

(485.1 mm)

 

 

 

72654-D

44.2"

36"

 

(1123.9 mm)

(918.4 mm)

 

 

``B"

72654-1-D

44.5"

36.2"

(924.7 mm)

(1130.2 mm)

 

 

 

FIGURE 1

 

 

Lower Pump

 

 

Mat’l Inlet

 

OPERATING AND SAFETY PRECAUTIONS

 

 

 

 

 

 

 

HEED ALL WARNINGS.

Do not operate pump continuously at speeds in excess of 75 cycles per min4

DO NOT EXCEED MAXIMUM WORKING PRESSURE OF 7,500 PSI (517

 

ute.

 

BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.

 

WARNING

: PREVENT STATIC SPARKING. If static sparking

 

 

 

 

 

 

 

 

WARNING

: HIGH PRESSURE DEVICE. Improper usage of

 

occurs, fire or explosion could result. Pump, dispensing

 

this equipment could result in serious injury. The possibility

 

valve and containers must be grounded when handling in!

 

of injection into the flesh is a potential hazard. Never allow any

 

flammable fluids such as petroleum products, paints, lac!

 

part of the human body to come in front of or in direct contact

 

quers, etc. and wherever discharge of static electricity is a

 

with the material outlet. An injection injury can be serious. If

hazard.

 

injection should occur, contact a qualified physician immedi!

Use grounded hoses (static wire) and be sure the object is grounded if it can

 

ately for treatment.

 

produce a static charge.

COMPONENTRUPTURE. This pump is capable of producing high material

Use grounded hoses (static wire) and be sure the object is

pressure as stated on pump model plate.

 

grounded if it can produce a static charge.

Be sure material hoses and other components are able to withstand fluid

Disconnect air line from pump air motor when system sits idle for long peri4

pressures developed by this pump.

ods of time.

 

THE ARO CORPORATION D ONE ARO CENTER D BRYAN, OHIO 43506–0151

&(419) 636–4242 D FAX (419) 636–2115

E1995 THE ARO CORPORATION D PRINTED IN U.S.A.

Page 1