Frequency/Voltage Control
CMOS Setup
Frequency/Voltage Control
CPU Clock Ratio | [15X] |
|
|
| Item Help | |
Auto Detect PCI/DIMM Clk | [Enabled] |
|
| Menu Level` | ||
Spread Specturm | [Enabled] |
|
|
|
| |
CPU Host Clock Control | [Disabled] |
|
|
|
| |
x CPU Clock |
| 100 |
|
|
|
|
DRAM Clock |
| [By SPD] |
|
|
|
|
AGP OverVoltage Control | [Auto] |
|
|
|
| |
DIMM OverVoltage Control | [Auto] |
|
|
|
| |
|
|
|
|
|
|
|
KLJI: Move | Enter: Select | F10: Save | ESC: Exit | F1: General Help | ||
F5: Previous Values | F6: |
| F7: Optimized Defaults | |||
|
|
|
|
|
|
|
Incorrect using these features may cause your system broken. For power
CPU Clock Ratio
This option will not be shown or not be available if you are using a CPU with the locked ratio.
15X~21X It depends on CPU Clock Ratio.
This setup option will automatically assign by CPU detection. For Willamette CPU: 8X~23X default: 14X
For
For Northwood CPU: 12X~24X default: 16X
The option will display "Locked" and read only if the CPU ratio is not changeable.
Auto Detect PCI/DIMM Clk
Enabled | Enable PCI/DIMM clock |
Disabled | Disable this function. |
Spread Spectrum
Enabled | Enable clock spread spectrum. (Default value) |
Disabled | Disable this function. |
CPU Host Clock Control
If system hangs up before enter CMOS setup utility, wait for 20 sec for times out reboot. When time out occur, system will reset and run at CPU default Host clock at next boot.
Disabled | Disable CPU Host Clock Control. (Default value) |
Enabled | Enable CPU Host Clock Control. |
CPU Clock
100MHz ~ 132MHz Set CPU Host Clock from 100MHz to 132MHz. (The values depend on CPU clock ratio.)
English