Intel MPRTM4808 manual 3.5.1Installation Procedure

Models: MPRTM4808

1 33
Download 33 pages 63.34 Kb
Page 18
Image 18
3.5.1Installation Procedure

Installation

Before touching integrated circuits, make sure that you are working in an ESD-safe environment.

When plugging the board in or removing it, use the handles; do not press on the front panel.

3.5.1Installation Procedure

Note: Connect interface cables to the on-board connectors first, since it may be difficult to reach them when the Intel MPRTM4808 board is already installed into the CompactPCI backplane. Connect interface cables to the front panel connectors after installing the Intel MPRTM4808 board.

1.Check all installed boards for steps to perform before turning off system power.

2.Turn off system power.

3.Check system documentation for switch settings.

4.The Intel MPRTM4808 board provides two on-board switches and one FP reset switch. Make sure that switches are set to OFF (default position)

5.Connect interface cables to on-board connectors.

6.Insert the Intel MPRTM4808 board carefully from rear into same slot as the CPU board, making sure not to bend any pins.

Figure 11. Connecting Intel® NetStructure™ MPRTM4808 Rear Transition Board to Backplane

 

 

CompactPCI Backplane

 

Front

Rear

 

CPU

 

 

RTB

Board

J5

J5

 

J3

J3

 

 

J2

 

 

 

J1

 

 

7.Press handles inward to lock Intel MPRTM4808 board on CompactPCI rack.

8.Fasten Intel MPRTM4808 board with screws.

9.Plug interface cables into front panel connectors, if applicable (see Section 3.7, “Front Panel Connectors and Controls” on page 22).

10. Turn on system power.

18

Intel® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide

Page 18
Image 18
Intel MPRTM4808 manual 3.5.1Installation Procedure