Troubleshooting
LED Information

The Intel® Server Board SE7320VP2 includes LEDs that can aid in troubleshooting your system. A

table of these LEDs with a description of their use is listed below.

Table 9. Keyboard Commands

LED Name Function Location Color Correction
ID Aid in serv er
identification from the
back panel
Control panel and
board rear left
corner
Blue Press ID LED button or user
Server Management
software to turn off the LED.
System fault Visible fault warning Control panel and
board rear left
corner
Green or Amber On = No Fault
Green Blink = degraded
Amber = critical error or
non-recoverable
Amber blink = non-critical
ATA drive
activity
Control panel Control panel and
board left side
Green Blinking = Activity. No action
required.
Memory fault
1–6
Identify failing memory
module
DIMM end rear of
board
Amber On = Fault
POST code 1–4
(LSB, bit1, bit2,
MSB)
Display boot 80 POST
code
Left rear of board Each LED can be
Off, Green,
Amber, Red
See the POST code table in
the Intel® Server Board
SE7530VP2 Technical
Product Specification
5v Standby Identify 5v standby
power on state
Front left board Amber On = 5v standby power on
Power LED Identify the power state
of the system
Control Panel Green Off = Power is off (off or
S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 – S3)

48