Table 6. Quality of Service

Specification Unit
Intel SSD DC S3500
Queue Depth=1
Queue Depth=32
80/120/160/
240 GB
300/400/480/
600/800 GB
80/120/160/
240 GB
300/400/480/
600/800 GB
Quality of Service
3, 4
(99.9%)
Reads
ms
0.5
0.5
2
2
Writes
ms
5
2
20
10
Quality of Service
3,4
(99.9999%)
Reads
ms
10
5
10
5
Writes
ms
10
10
30
30
Notes:
1. Device measured using Iometer. Latency measured using 4 KB (4,096 bytes) transfer size with Que ue Depth eq u al t o 1 on a
sequential workload.
2. Power On To Ready time assumes proper shutdown. Time varies if shutdown is not preceded by STANDBY IMMEDIATE command.
For 95% of the time, the maximum time for power on to ready will be less than 10 seconds.
3. Device measured using Iometer. Quality of Servic e measured using 4 KB (4,096 bytes) transfer size on a random workload on a
full Logical Block Address (LBA) span of the drive once the workload has reached steady state but including all background
activities required for normal operation and data reliability.
4. Based on Random 4KB QD=1, 32 workloads, measured as the time taken for 99.9(or 99.9999) percent ile of commands to finish
the round-trip from host to drive and back to host.
2.3 Electrical Characteristics

Table 7. Operating Voltage for 2.5-inch Form Factor

Electrical Characteristics
Intel SSDDC S3500
80 GB, 120 GB, 160 GB, 240 GB, 300 GB, 480 GB, 600 G B, 800 GB
5 V Operating Characteristics:
Operating Voltage range
Rise time (Max/Min )
Fall time (Min)2
Noise level
Min Off time3
Inrush Current (Typical Peak)
1
5 V (±5%)
1 s / 1 ms
1 ms
500 mV pp 10 Hz 100 KHz
50 mV pp 100 KHz 20 MHz
500 ms
1.0 A, < 1 s
12 V Operating Characteristics:
Operating Voltage range
Rise time (Max/Min )
Fall time (Min)2
Noise level
Min Off time3
Inrush Current (Typical Peak)
1
12 V (±10%)
1 s / 1 ms
1 ms
1000 mV pp 10 Hz 100 KHz
100 mV pp 100 KHz 20 MHz
500 ms
1.0 A, < 1 s
Notes:
1. Measured from initial device p ower supply application.
2 Fall time needs to be equal or better than minimum in order to guarantee full functionality of enhanced power loss management.
3. The drive needs to be powered off for at least 500msec before powering on.