SECTION 14 INPUTS
An open collector output is recommended
when interfacing with the IM481H.
On power up, or if the Reset Input is Closed,
the internal reset circuit will hold the input
low for 100 to 300 milliseconds. The
“holding” time does not begin until the Reset
Input is Opened. (See Figure 9.)
18
The inputs to the IM481H are internally pulled up
to the +5VDC internal supply. Figure 7 shows the
inputs and their associated pull up resistor
values. See Section 4, Electrical Specifications,
for resistor tolerence.
Figure 7
W A R N I N G! When interfacing the FAULT IN or RESET input, an
open collector, tri-state output, or a blocking diode is REQUIRED or
damage may occur to internal circuits. (See Figure 8.)
1N914 OREQUIVALENT
1N914 OR EQUIVALENT
1N914 OR EQUIVALENT
RESETBUTTONRESETINPUTUNIT #1RESETINPUTUNIT #2RESETINPUTUNIT #313
13
13
1N914 OR EQUIVALENTINTERFACECIRCUITORFAULT IN/RESET INPUTFAULT IN /RESET INPUT