28
1 Ampere (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 20 18 18 16
2 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 18 16 14 14
3 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12 12
4 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12 12
5 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
16 16 14 12 12
6 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
14 14 14 12 12
7 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
12 12 12 12 12
* Use the alternate method illustrated in Example B
when cable length is
50 feet.
IMS Driver to Motor Cable AWG Table
Driver to Motor Supply Cable Wire Size

NOTE: These recommendations will provide optimal

protection against EMI and RFI. The actual cable type,

wire gauge, shield type and filtering devices used are dependent on

the customer’s application and system.

NOTE: Always use Shielded/Twisted Pairs for the IMS Driver

DC Supply Cable, the AC Supply Cable and the IMS Driver to

Motor Cable.