RCM-810 Block Diagram

 

 

 

 

 

 

 

 

 

 

 

 

Only 2 Channel AMP

+15V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AGND

 

 

 

 

 

 

 

 

-15V

 

 

 

 

 

 

SRAM

 

U-TEMP

 

 

 

 

 

 

 

 

VOLTAGE A+ / B+

 

 

 

Isolation

 

 

 

 

VOLTAGE A- / B-

REMOTE

 

 

 

 

 

 

 

 

 

Galvanic

 

 

 

 

 

CAN BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT A+ / B+

 

 

 

 

 

 

Latch

 

CURRENT A- / B-

 

 

 

 

 

 

TEMP_Board

 

 

 

 

 

 

 

 

 

 

 

 

DC

+5V

 

 

 

 

 

 

 

CAN-LED

 

 

 

 

 

 

 

DC

 

 

 

 

LIMIT /

 

 

 

 

 

 

 

 

 

1

2 3 4 5 6

 

 

 

 

 

PROTECT /

CAN

7

 

 

 

 

 

REDUCTION

0

8

 

 

 

 

 

F

9

 

 

 

CAN

 

 

 

E D C BA

 

 

 

 

 

ADDRESS

1

2 3 4 5 67

P/S

 

CAN-LED

 

ADC

 

 

0

8

 

 

 

 

FE D C BA9

 

Test

 

 

 

 

 

 

 

 

 

 

INIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Tone

 

 

 

 

 

 

Reset

 

Detection

 

 

 

 

 

+5V

Controller

 

 

 

 

 

 

Watchdog

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDBY

 

 

 

 

 

 

 

 

BRIDGED

 

 

 

 

 

 

 

 

IrisNet LED

 

 

 

 

 

 

 

 

MUTE A / B

 

 

 

 

 

 

 

 

POWER ON

 

 

 

 

 

 

 

 

AMP ID

CONTROL

+5V

 

 

 

 

 

 

 

 

 

 

+15V

PORT

 

 

 

 

 

 

 

 

 

 

AGND

 

 

 

 

 

-15V

 

 

 

 

 

 

 

 

/RCM_DETECT

 

 

 

 

 

 

 

 

POWER_GOOD

 

 

 

 

 

 

 

 

/ATMEL_PROG

 

 

 

 

 

 

 

 

DGND

 

 

 

 

 

 

 

 

+5V

 

 

 

 

 

 

 

 

/RCM_EN

 

 

 

 

 

 

 

 

RCM_CLK

 

 

 

FRAM

 

 

 

 

RCM_MOSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCM_MISO

Technical Specifications

NETWORK AND GENERAL FEATURES

Remote Control and Software

IRIS-Net, Multiple PCs possible, MS Windows 2000, XP, Vista

Maximum Configuration

250 Amplifiers in total, 100 Amplifiers per CAN bus, 1000 meter cable run

Amplifier Supervision

Operation mode, temperature, output voltage and current, impedance of

 

connected speakers, protection mode status, pilot tone detection

Network Supervision

CAN bus failures, defective or missing amplifiers, bandwidth, failure protocol

 

and messaging

INTERFACES

 

CAN

10…500 kbaud, 2 x RJ-45 (IRIS-Net Control)

GPIO Control Port

2 x 3-pole Euro block

 

2 Control Inputs

 

2 Control Outputs

 

2 Reference Outputs (+5 V, 200 mA / GND)

RCM-810 GENERAL SPECIFICATIONS

Supply Voltage/Current

+5 V DC / 320 mA

 

+15 V DC / 80 mA

 

-15 V DC / 80 mA

Power Consumption

4 W

Operating Temperatur Range

0 °C...40 °C

Dimensions (W x H x D)

103.5 x 37 x 103 mm

Weight

115 g

ACCESSORIES

3-pole Euro block connector

For GPIO Control Port

GmbH • Hirschberger Ring 45 • 94315 Straubing • Telefon (09421) 706-0 • Telefax (09421) 706-265

Subject to change without prior notice. Printed in Germany Vs 02 10.03.2009

D367600 / F01U108146

Page 2
Image 2
IRIS owner manual RCM-810 Block Diagram, Technical Specifications