SECTION 5: PARTS SECTION
RINSE SOLENOID VALVE & VACUUM BREAKER REPAIR PARTS KITS
Data Plate
Valve Bonnet
Spring position is moved for clarity.
Goes below the plunger.
Diaphragm
Retainer
Screen
Retainer
Valve Body
Screw
Coil & Housing
Spring
Plunger
Diaphragm
Mesh Screen
Cap Screw
Data Plate
Cap
Cap Retainer |
|
| |
Components of | Plunger |
| |
Repair Kit |
|
Body | |
|
Complete Vacuum Breaker Assembly, 3/4” NPT
Complete 110 Volt Solenoid Valve Assembly, 3/4”
Coil & Housing only, 3/4”
Possible Problems:
1.Pilot port extension #1 clogged. Clean hole.
2.Hole #2 Clogged. Pass heated straight pin through hole.
DISASSEMBLY - These valves may be taken apart by unscrewing the bonnet and the enclosing tube assembly from the valve body assembly. After unscrewing, carefully lift off the bonnet and enclosing tube assembly. Don’t drop the plunger. The
TO REASSEMBLE - Place the diaphragm cartridge in the body with the pilot port extension UP. Hold the plunger with the synthetic seat against the pilot port. Make sure the
1
2
Issued:
70