SECTION 5: PARTS SECTION

DRAIN VALVE HANDLE ASSEMBLY/DRAIN QUENCH SYSTEM

Drain Valve Handle

Sleeve 05700-000-01-53

Drain Quench Assembly

06401-002-44-07

Nipple, 1-1/2” NPT 04730-207-40-00

Modified Compression Fitting

05700-001-16-52

Reducer, 1-1/2” x 1/4”

04730-002-55-76

To Dishmachine Drain

Tee, 1-1/2” x 1-1/2” x 1-1/2”

 

 

04730-011-69-93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reducer, 1-1/2” to 1/2”

 

Valve, Check, 1/2”

 

04730-002-55-75

 

(Not Shown)

 

 

 

 

04820-002-55-77

 

 

 

 

 

 

 

 

 

 

Handle Weldment 05700-021-70-45

Lid, Drain Quench

05700-002-67-16

Thermostat 05930-003-13-65

Solenoid Valve 04810-100-09-18

To Cold Water Supply

Box, Drain Quench 05700-002-69-96

Nipple, Close, 1/2” NPT (Not Shown)

04730-207-15-00

From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” Reducer. Position the bulb of the thermostat so that it rests approximately 1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.

AJ-64 Conveyor Series Technical Manual 7610-003-30-93

Issued: 05-02-2006 Revised: N/A

85

Page 33
Image 33