SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for reference and may change without notice at any given time.
| RINSE |
| TYPICAL | ||
|
|
|
| ||
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATING | AMPS | CIRCUIT |
208 | 1 | 60 | N/A | 83 Amps | 110 Amp |
230 | 1 | 60 | N/A | 76 Amps | 100 Amp |
208 | 3 | 60 | N/A | 49 Amps | 70 Amp |
230 | 3 | 60 | N/A | 45 Amps | 60 Amp |
460 | 3 | 60 | N/A | 23 Amps | 30 Amp |
600 | 3 | 60 | N/A | 19 Amps | 25 Amp |
RINSE |
| TYPICAL | |||
|
|
|
| ||
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATING | AMPS | CIRCUIT |
208 | 1 | 60 | N/A | 12 Amps | 15 Amp |
230 | 1 | 60 | N/A | 12 Amps | 15 Amp |
208 | 3 | 60 | N/A | 8 Amps | 15 Amp |
230 | 3 | 60 | N/A | 8 Amps | 15 Amp |
460 | 3 | 60 | N/A | 5 Amps | 15 Amp |
| RINSE |
| TYPICAL | ||
|
|
|
| ||
VOLTS | PH | HZ | HEATER | TOTAL | ELECTRICAL |
RATING | AMPS | CIRCUIT | |||
208 | 1 | 60 | N/A | 89 Amps | 125 Amp |
230 | 1 | 60 | N/A | 82 Amps | 110 Amp |
208 | 3 | 60 | N/A | 52 Amps | 70 Amp |
230 | 3 | 60 | N/A | 48 Amps | 60 Amp |
460 | 3 | 60 | N/A | 24 Amps | 30 Amp |
600 | 3 | 60 | N/A | 22 Amps | 30 Amp |
RINSE |
| TYPICAL | |||
|
|
|
| ||
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATING | AMPS | CIRCUIT |
208 | 1 | 60 | N/A | 18 Amps | 25 Amp |
230 | 1 | 60 | N/A | 18 Amps | 25 Amp |
208 | 3 | 60 | N/A | 12 Amps | 15 Amp |
230 | 3 | 60 | N/A | 12 Amps | 15 Amp |
460 | 3 | 60 | N/A | 7 Amps | 15 Amp |