Electrical Connections

J-Sha II Owner's Manual

Electrical Connections

Two separate circuits are required for this unit:

1.Whirlpool bath controller.

2.Rapid Heat.

1. J-Sha II

Install a 120 VAC 20 AMP dedicated circuit protected by a Ground Fault Circuit Interrupter (GFCI).

DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit

Interrupter.

2. Rapid Heat

Install a 120 VAC 15 AMP dedicated circuit with GFCI protection. For operation, refer to the RapidHeat in- structions.

DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Interrupter.

ELECTRICAL CONNECTION

CONTROL

BOX

 

WARM

PROTECTIONOVER

SEPERATE GFCI

 

 

HEAT

PROTECTED

 

HOT

RESET

 

 

TO

 

 

 

PUSH

 

HEATER "ON"

MIN

 

CIRCUITS

 

.

 

 

 

 

 

RAPID HEAT

Service Access

For partially or fully sunken installations, allow for service access as shown. It is the installer's responsi- bility to provide sufficient service access. Provide adequate ventilation to cool the motor and to supply sufficient air for the jets.

PROVIDE SERVICE ACCESS TO

THE THREE SIDES AS SHOWN

In some cases, access may not have been provided because of the design of the bath environment and having full understanding that in this case, it may be necessary to remove the unit for service.

If this is the case, diagnosing a problem may not be possible without complete access to the plumbing sys- tem. This would necessitate the removal of the unit. Although this practice is not commonly implemented, it is an acceptable method.

SERVICE ACCESS

AREA

A

AREA

B

MOTOR

In some cases access may have been provided in Area A but service is required in Area B which requires the unit to be pulled for service and reinstalled.

If service access has not been provided, it is the home owners responsibility to remove the bath and provide the required access, should a repair be- come necessary.