Page 9 TM-6760 Series Progressive Scan Shutter Cameras

2.2.2 (e) Analog Output Connector

The TM-6760 has a BNC connector on the rear panel to output analog video data.

2.2.3Shutter Speed Control Dial (TM-6760 only)

Shutter speed can be selected by switching the shutter dial to the appropriate setting (0 through 9). The factory default settings correspond to the shutter speeds as shown in below.

TABLE 5. Shutter Speed Control Dial

 

Shutter Exposure Time (Seconds)

 

 

 

 

Normal

Async

 

 

 

0

No shutter (1/60)

no shutter (1/60)

 

 

 

1

1/125

1/32,000

 

 

 

2

1/250

1/16,000

 

 

 

3

1/500

1/8,000

 

 

 

4

1/1,000

1/4,000

 

 

 

5

1/2,000

1/2,000

 

 

 

6

1/4,000

1/1,000

 

 

 

7

1/8,000

1/500

 

 

 

8

1/16,000

1/250

 

 

 

9

1/32,000

Ext. pulse width con-

 

 

trol

 

 

 

8 7

9

6

0

5

1 2

3 4

2.2.4RS-232 Communication Cable (TM-6760 only)

FIGURE 5. Serial Communication Cable RS-232B-12

2000±20mm

40±3mm 1925±10mm

Receptacle

75mm±5mm 190±5mm

1 6

5 9

Jack

The RS-232 controller set CS-232E includes cable RS-232B-12 interface cable, software disk, and a quick-start card. The TM-6760 camera’s built-in look-up table (LUT) can be controlled by an external RS-232 interface. The camera settings can be programmed or changed using the communication cable and software. Commands from the RS-232 interface will override the rear panel switch settings of the camera. Please refer to the camera control software manual for details on the graphical user interface.