Page 15
TM-6760 Series Progressive Scan Shutter Cameras
the
TABLE 6. Mode Selection Switch
Mode
Selection
Switch
Position
Mode Information
Up/Down Switch
Functions
0 | Switch disabled | Switch disabled | None |
|
|
|
|
1 | Set Gain | Up / Down | Change gain |
|
|
|
|
2 | Set Vtop (A/D) | Up / Down | Change A/D ref. top |
|
|
|
|
3 | Set Vbottom(A/D) | Up / Down | Change A/D ref. bot- |
|
|
| tom |
|
|
|
|
4 | Gain Selection #1 | Up: 9dB, Down: 12dB | Lower gain selection |
|
|
|
|
5 | Gain Selection #2 | Up: 18dB, Down: 22dB | Higher gain selection |
|
|
|
|
6 | Linear LUT | Up | Back to linear table |
|
|
|
|
7 | Knee Selection | Up / Down (Scroll) | Scroll 8 different |
|
|
| LUTs |
|
|
|
|
8 | Async Reset Mode | Up: Normal, Down: | Async and normal |
|
| Async | shutter |
|
|
|
|
9 | Factory default | Up / Down: Recall | Factory setting |
| Recall |
|
|
|
|
|
|
A | Power up Setting | Up: Recall, Down: Save | Power up page setting |
|
|
|
|
B | User Page Storage | Up: Recall, Down: Save | User page storage set- |
| #1 |
| ting |
|
|
|
|
C | User Page Storage | Up: Recall, Down: Save | User page storage set- |
| #2 |
| ting |
|
|
|
|
D | Direct Shutter Con- | Up: Increment | Change “Direct shutter |
| trol | Down: Decrement | speed in 1H incre- |
|
|
| ments |
|
|
|
|
E | Scan Format2 | Up: PS200 Lines | Scan mode |
|
| Down: |
|
|
|
|
|
F | Scan Format1 | Up: 60fps, Down: 30fps | Scan mode |
|
|
|
|
Operation