Jasco ZWAVEKIT manual Valid Values

Models: ZWAVEKIT

1 24
Download 24 pages 42.36 Kb
Page 20
Image 20

- Valid Values:

Parameter 7 (default = 1) Valid Values: 1-99

Parameter 8 (default = 3) Valid Values: 1-255

2. Manual Control Dimming (pressing the Dimmer’s rocker)

-Parameter 9 (number of steps or levels)

-Parameter 10 (timing of the steps)

-Length: 1 Byte

-Valid Values:

Parameter 9 (default = 1) Valid Values: 1-99

Parameter 10 (default = 3) Valid Values: 1-255

3.When Receiving an All-On or All-Off Command - Parameter 11 (number of steps or levels)

- Parameter 12 (timing of the steps) - Length: 1 Byte

- Valid Values:

Parameter 11 (default = 1) Valid Values: 1-99

Parameter 12 (default = 3) Valid Values: 1-255

Ignore Start Level When Receiving Dim Commands Please note: Every “Dim” command includes a start level embedded in it.

The 45607 can be set to ignore the start level that is part of the dim command. Setting parameter 5 to a value of 0 will cause the 45607 to dim or brighten from the start level embedded in the command.

-Parameter No: 5

-Length: 1 Byte

-Valid Values = 0 or 1 (default 1)