SAFETY INFORMATION

Warning

Any person performing service of this unit will be exposed to hazardous voltages and the risk of electric shock. It is assumed that any person who removes the amplifier from this cabinet has been properly trained in protecting against avoidable injury and shock. Therefore, any service procedures are to be performed by qualified service personal ONLY!

Caution

Early revisions of the unit did not have a power switch. Hazardous voltages are resent within the unit whenever it is plugged in.

Before amplifier is plugged in, be sure its rated voltage corresponds to the voltage of the AC power source to be used. Incorrect voltage could cause damage to the amplifier when the AC power cord is plugged in. Do not exceed rated voltage by more than 10%: operation below 90% of rated voltage will cause poor performance or may shut the unit off.

Leakage/Resistance Check

Before returning the unit to the customer, perform a leakage or resistance test as follows:

Leakage Current. Note there is no power switch on early revisions of this unit. When the power plug is plugged in, the unit is live. Connect the unit to its rated power source. Using an ammeter, measure the current between the neutral side of the AC supply and chassis ground of the unit under test. If leakage current exceeds 0.5mA, the unit is defective. Reverse the polarity of the AC supply and repeat.

Resistance. Measure the resistance from either side of the line cord to chassis ground, If it is less than 500k ohms, the unit is defective.

WARNING! DO NOT return the unit to the customer if it fails one of these tests until the problem is located and corrected.

Critical Components

All components identified with the IEC symbol in the parts list and schematic diagram designate components in which safety can be of special significance when replacing identified with. Use only the

replacement parts designated in the parts list or parts with the same rating of resistance, wattage or voltage.

List of Safety Components

Requiring Exact Replacements

Part Number/

Description

Designator

 

 

 

F1

Line Fuse Slo Blo 2.0A

093-105202-300

5x20mm

083-041802-009

250V UL approved SPT-2 or

 

better with polarized plug, UL

 

approved wired with the hot side

 

to fused

 

side. Use with factory

 

replacement panel strain relief

 

(70305) only.

 

 

PT1

Power Transformer.

Use only factory

042-010053-003

replacement.

 

 

 

BR1

Bridge diode. Use only

052-400080-000

factory replacement.

 

3300uF 80V electrolytic

 

filter caps. Be sure

 

replacement part is at

C6,8

least the same working

voltage and capacitance

034-330780-300

rating. Also the lead

 

spacing is important.

 

Incorrect spacing may

 

cause premature failure

 

due to internal cabinet

 

pressure and vibration.

 

 

 

Rear Amp Cover

063-531808-000

Use only factory

 

replacement

Inductor

L1 - Use only factory

043-560200-000

replacement

Inductor

L2 - Use only factory

043-300101-000

replacement

Inductor

L3 - Use only factory

043-700101-000

replacement

Inductor

L4 - Use only factory

043-324300-000

replacement

 

 

2