WIRING INSTRUCTIONS
Control Contractor 40 Series
Connecting the Wiring to the Euroblock
locking connector that is INCLUDED with |
5.Close the input terminal cover and tighten the terminal cover screws.
6.Allowing sufficient strain relief slack for the input wiring and
the speaker by stripping the insulation back about 5 mm (about 3/16 inch), inserting the bare end of wire into the connector and screwing down the
Tighten any unused screws to avoid vibration. Using terminal block connectors
allows the system to be
When wiring Control Contractor 40 Series loudspeakers, always use proper electrical wiring practices in accordance with your area’s building
NOTE: The input terminal cover on Control Contractor 40 Series loudspeakers includes a .75 in (19 mm) knockout for an additional conduit clamp. This knockout point can be used in addition to the conduit connector located on the top of the can and is useful for wiring loop- thru runs or when access is limited on the top of the can.
Knockout |
codes and regulations.
Connecting the Input Terminal Block on Control Contractor 40 Series Loudspeakers
cover on all Control Contractor 40 Series are fitted with a conduit connector for securing wiring conduit to and from the unit. To wire the unit:
Guide to Connection Pins on Control 40 Loudspeakers
--There are two (2) removable locking input connectors with two (2) terminals on each for the Control 42C, Control 47C/T, Control 47LP and Control 47HC and six (6) terminals on the Control 40CS/T. The pin functions are listed on the label located on the can.
Control 42C: | Control 40CS/T: |
1.Loosen the screw on top of the input terminal cover and then remove (and save) the input terminal cover screw on the side of the can.
2.Swing open the input terminal cover and remove the euroblock connector.
3.Insert the bare ends of wire into the Euroblock connector and secure the wires with the
Connecting the Wiring to the Euroblock)
+ | - | + | - |
IN | IN | Loop Loop | |
|
| Thru | Thru |
Control 47C/T, LP & HC:
+-
IN IN
+-
+ | - | + | - |
Sat 3 | Sat 4 | ||
+ | - | + | - |
Sat 1 | Sat 2 | ||
+ | - | + | - |
IN | IN | Loop Loop | |
|
| Thru Thru |
- +
Euroblock Connector
Conduit Connector
4.Loosen the conduit connector on the input terminal cover and insert the wired euroblock
connector | through |
the conduit | connector |
opening. Connect the euroblock to the matching receptacle.
Loop Loop
Thru Thru
To wire Control 40 Series loudspeakers simply connect the positive wire to the “+” pin and connect the negative wire to the
To select the operating mode or desired output tap of the loudspeaker, simply rotate the tap selector switch located on the front of the baffle to the desired setting.
Note: Both 70V/(100V) connections and low impedance connections are made via the same input pins. When using the transformer tap selections, be sure that the power amplifier is set on 70V/(100V) mode and the leads feeding the system are connected to 70V/(100V) outputs on the amplifier.