2-pin Connector

WIRING INSTRUCTIONS

Control Contractor 40 Series in-ceiling loudspeakers include Euroblock locking input connectors that allow the system to be “pre-wired”.

Connecting the Wiring to the Euroblock

-- Connect the wiring to the removable

locking connector that is INCLUDED with

5.Close the input terminal cover and tighten the terminal cover screws.

6.Allowing sufficient strain relief slack for the input wiring and re-tighten the conduit connector on the terminal cover.

the speaker by stripping the insulation back about 5 mm (about 3/16 inch), inserting the bare end of wire into the connector and screwing down the hold-down screw until tight using a small flatblade screwdriver.

Tighten any unused screws to avoid vibration. Using terminal block connectors

allows the system to be pre-wired before final installation of the product.

When wiring Control Contractor 40 Series loudspeakers, always use proper electrical wiring practices in accordance with your area’s building

NOTE: The input terminal cover on Control Contractor 40 Series loudspeakers includes a .75 in (19 mm) knockout for an additional conduit clamp. This knockout point can be used in addition to the conduit connector located on the top of the can and is useful for wiring loop- thru runs or when access is limited on the top of the can.

Knockout

codes and regulations.

Connecting the Input Terminal Block on Control Contractor 40 Series Loudspeakers -- The input terminal

cover on all Control Contractor 40 Series are fitted with a conduit connector for securing wiring conduit to and from the unit. To wire the unit:

Guide to Connection Pins on Control 40 Loudspeakers

--There are two (2) removable locking input connectors with two (2) terminals on each for the Control 42C, Control 47C/T, Control 47LP and Control 47HC and six (6) terminals on the Control 40CS/T. The pin functions are listed on the label located on the can.

Control 42C:

Control 40CS/T:

1.Loosen the screw on top of the input terminal cover and then remove (and save) the input terminal cover screw on the side of the can.

2.Swing open the input terminal cover and remove the euroblock connector.

3.Insert the bare ends of wire into the Euroblock connector and secure the wires with the hold-down screws. (see

Connecting the Wiring to the Euroblock)

+

-

+

-

IN

IN

Loop Loop

 

 

Thru

Thru

Control 47C/T, LP & HC:

+-

IN IN

+-

+

-

+

-

Sat 3

Sat 4

+

-

+

-

Sat 1

Sat 2

+

-

+

-

IN

IN

Loop Loop

 

 

Thru Thru

- +

Euroblock Connector

Conduit Connector

4.Loosen the conduit connector on the input terminal cover and insert the wired euroblock

connector

through

the conduit

connector

opening. Connect the euroblock to the matching receptacle.

Loop Loop

Thru Thru

To wire Control 40 Series loudspeakers simply connect the positive wire to the “+” pin and connect the negative wire to the “-” pin. The “IN” pins are paralled to the “LOOP THRU” pins (+ and - respectively) inside the loudspeaker. The “Loop Thru” pins allow a parallel connection to an additional loudspeaker.

To select the operating mode or desired output tap of the loudspeaker, simply rotate the tap selector switch located on the front of the baffle to the desired setting.

Note: Both 70V/(100V) connections and low impedance connections are made via the same input pins. When using the transformer tap selections, be sure that the power amplifier is set on 70V/(100V) mode and the leads feeding the system are connected to 70V/(100V) outputs on the amplifier.