Installation

Installing Bottom Trim Piece WARNING

Improper installation of the grounding circuit can result in a risk of electric shock.

Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, if doubt exists as whether the appliance is properly grounded.

CAUTION

For European style cabinets (flush front) the required clearance for operation of the oven door is minimum spacing of 7/8￿ between the cutout and the door, hinge or drawer of the cabinet.

Some built-in cabinets may not be wide enough, due to their construction, to allow this installation.

Installation

1.Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight.

NOTE: There are no provisions to level the unit after it is installed. An oven that is not level could cause poor baking results.

2.Install plywood floor as shown.

3.Remove oven door(s). See Oven Door Removal procedure.

4.Attach unit to the cabinet with four No. 8 x 1￿ screws supplied with unit inside of envelope containing these instructions. Pre-drill holes in cabinet for attachment screws using 1/8￿ drill. Oven mounting holes are provided in side trim.

5.Install bottom trim.

6.Replace oven door(s). See Oven Door Replacement procedure.

7.See instructions at right for electrical hook-up.

8.See Use and Care Manual for operating instructions.

Installing Bottom Trim Piece

Remove lower screws from hinge receptacle plates. Align lower trim and reinstall screws.

DO NOT INSTALL BOTTOM TRIM UNTIL UNIT IS ATTACHED TO THE CABINET.

Electrical Connections

Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.

It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.

120/240 VAC or 120/208 VAC 60 Hz. See serial plate on front of unit for power requirements.

The neutral of this unit is grounded to the frame through the green or solid grounding wire. (The green and the white wires are twisted together at the termination of the conduit.) If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the green wire and connect the green wire to ground in accordance with local code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.

The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit.

K.W. RATING

RECOMMENDED MINIMUM

WIRE SIZE

CIRCUIT PROTECTION

ON SERIAL PLATE

IN AMPERS

(AWG)

0

-

4.8

20

12

4.9

-

6.9

30

10

7.0

-

9.9

40

8

10.0

-

11.9

50

8

12.0

- 14.9

60

6

 

 

 

 

 

Service

Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this could result in a dangerous or even fatal shock.