INSTALLATION
11)Insert a 5/32” or 4mm Allen wrench into the hexagonal
15)Verify that if the conversion is from NG to LPG, the screw must be
Installation of the DC Sparker:
24)Locate the Piezo Ignitor situated at the side of the valve.
Red
Fig.5
LPG Configuration
Fig.2
12)Check that the screw is clean and if necessary remove dirt.
13)Flip the screw (Fig. 3).
Fig.3
14)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.
16)
Fig.6
WARNING!
Also check that the pilotand main burner injectors are appropriate for the gas type.
25)RemovethePiezoIgnitorbyunscrewingthe nut at the back of the mounting bracket.
IgnitorWire
Piezo
Ignitor
26)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.
DCSparker
Ignitor
Wire
Fig.4
WARNING!
Do not overtighten the screw. Recommended togrip the wrench by the short side.17)Reverse steps 4) to 1).
18)Attach the label "This unit has been converted to LPG" near or on top of the serial # decal.
19)Replace yellow "Natural Gas" label with red "Propane" label
20)Check for gas leaks.
21)Check inlet and outlet pressures.
22)Check operation of fl ame control.
23)Check for proper fl ame appearance and glow on logs.
27)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.
28 | Regency® |