Regency P48-2 Installation of the DC Sparker, Also check that the pilot, Piezo Ignitor

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 28
Image 28
Installation of the DC Sparker:

INSTALLATION

11)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

15)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5).

Installation of the DC Sparker:

24)Locate the Piezo Ignitor situated at the side of the valve.

Red o-ring visible

Fig.5

LPG Configuration

Piezo Ignitor

Fig.2

12)Check that the screw is clean and if necessary remove dirt.

13)Flip the screw (Fig. 3).

Fig.3

14)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

16)Re-assemble the black protection cap (Fig. 6).

Fig.6

WARNING!

Also check that the pilot

and main burner injectors are appropriate for the gas type.

25)RemovethePiezoIgnitorbyunscrewingthe nut at the back of the mounting bracket.

Ignitor

Wire

Piezo

Ignitor

26)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.

DC

Sparker

Ignitor

Wire

Fig.4

WARNING!

Do not overtighten the screw. Recommended togrip the wrench by the short side.

17)Reverse steps 4) to 1).

18)Attach the label "This unit has been converted to LPG" near or on top of the serial # decal.

19)Replace yellow "Natural Gas" label with red "Propane" label

20)Check for gas leaks.

21)Check inlet and outlet pressures.

22)Check operation of fl ame control.

23)Check for proper fl ame appearance and glow on logs.

27)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.

28

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

Page 28
Image 28
Regency P48-2 Installation of the DC Sparker, Also check that the pilot, Do not overtighten the screw. Recommended to