Regency P48-2 installation manual Installation, Horizontal Venting with Two 2 90o Elbows

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 18
Image 18
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these options, maximum

A)

1'

Min.

3' Max.

total pipe length is 30 feet

B)

2'

Min.

4' Max.

with minimum of 6 feet total

 

 

 

 

vertical and maximum 8 feet

C)

3'

Min.

5' Max.

total horizontal.

D)

4'

Min.

6' Max.

Please note minimum 1

 

 

 

 

foot between 90o elbows is

E)

5'

Min.

7' Max.

required.

F)

6'

Min.

8' Max.

 

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

H

V

H+H1+H2

With these options, max.

A)

1'

Max.

1' Min.

3' Max.

totalpipelengthis30feet

B)

2'

Max.

3' Min.

5' Max.

with min. of 11 feet total

 

 

 

 

 

vertical and max. 9 feet

C)

3'

Max.

5' Min.

6' Max.

total horizontal.

D)

4'

Max.

7' Min.

7' Max.

Please note min. 1 foot

 

 

 

 

 

between 90o elbows is

E)

5'

Max.

9' Min.

8' Max.

required.

F)

6'

Max.

11' Min.

9' Max.

 

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

H

V

H + H1

A)

1'

Max.

1' Min.

3' Max.

B)

2'

Max.

2' Min.

5' Max.

C)

3'

Max.

4' Min.

6' Max.

D)

4'

Max.

6' Min.

7' Max.

E)

5'

Max.

8' Min.

8' Max.

 

 

 

 

 

With these options, max. total pipe length is 30feetwithmin.of8feet total vertical and max. 8 feet total horizontal.

Pleasenotemin.1foot between 90o elbows is required.

18

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

Page 18
Image 18
Regency P48-2 Installation, Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows