INSTALLATION

 

 

 

INSTALLATION

UNIT ASSEMBLY

TOP FACING SUPPORT AND

"C" Screw Position:

PRIOR TO

SIDE NAILING STRIPS

For a facing material depth of 1-1/4" (32mm),

 

 

Determine the total thickness of facing material

the top facing support must be reversed.

INSTALLATION

 

(e.g. drywall

plus ceramic tiles) to allow the

 

The Top Facing Support, the Side Nailing Strips

fi nished surface to be fl ush with the front of the

 

unit. Total facing thickness can vary from 1/2"

 

and the 2 Top Standoffs must be correctly

(13mm) to 1-1/4" (32mm) thick.

 

positioned and attached to the top before unit

 

 

 

is slipped into position.

TheTopFacingSupport&SideNailingStripscan

 

TOP STANDOFF ASSEMBLY

be mounted in 3 different positions depending

 

on the thickness of the facing material.

 

The top standoffs are shipped in a fl at position

 

 

 

and must be folded into shape and attached.

 

 

 

1) Remove the standoffs from the fi replace

Screw

Facing Material Depth

 

Position

 

 

top.

 

 

A

1/2" / 13mm

 

 

 

2) Take each standoff and bend into the correct

B

7/8" / 22mm

 

shape. Bend up at the bend lines until the

 

C*

1-1/4" / 32mm

2) Use the same screw hole position for the

screw holes in the standoff and the pre-

punched screw holes on the fi replace

top

 

 

Side Nailing Strips as was used for the Top

line up.

* For "C" screw position the top facing support

Facing Support. Attach each side nailing

is reversed.

 

strip using 3 screws.

 

 

3) Attach the standoff securely to the

top

 

 

 

with 2 screws per standoff (on opposite

 

 

 

corners).

1)

Mount Top Facing

Support using the 3

 

 

 

 

 

supplied screws into the three pre-punched

 

 

 

screw holes on the top front of the unit. Use

VENTING

 

 

hole positions A, B, or C depending on your

 

 

facing depth.

 

INTRODUCTION

 

 

 

 

 

 

 

 

The P48-2 uses the "balanced flue" technology

 

 

 

 

Co Axial system. The inner liner vents products

 

 

 

 

of combustion to the outside while the outer

 

 

 

 

liner draws outside combustion air into the

 

 

 

 

combustion chamber thereby eliminating the

 

 

 

 

need to use heated room air for combustion and

 

 

 

 

losing warm room air up the chimney.

 

 

 

 

Note: These flue pipes must not be

 

 

 

 

connected to any other appliance.

 

 

 

 

The gas appliance and vent system must be

 

 

 

 

vented directly to the outside of the building,

 

 

 

 

and never be attached to a chimney serving a

 

 

 

 

separate solid fuel or gas burning appliance.

 

 

 

 

Each direct vent gas appliance must use it's own

 

 

 

 

separate vent system. Common vent systems

 

 

 

 

are prohibited.

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

11