Regency P48-2 installation manual Installation, Horizontal Venting with Three 3 90o Elbows

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 19
Image 19
Vertical Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H

V + V1

H + H1

With these options,

 

 

 

 

 

 

 

max.totalpipelength

A)

2'

Min.

1' Max.

3'

Min.

4' Max.

is 30 feet with min. of

B)

3'

Min.

2' Max.

4'

Min.

5' Max.

12 feet total vertical

 

 

 

 

 

 

 

and max. 9 feet total

C)

4'

Min.

3' Max.

6'

Min.

6' Max.

horizontal.

D)

5'

Min.

4' Max.

8'

Min.

7' Max.

Please note min.

 

 

 

 

 

 

 

1 foot between

E)

6'

Min.

5' Max.

10'

Min.

8' Max.

90 o elbows is

F)

7'

Min.

6' Max.

12'

Min.

9' Max.

required.

Vertical Venting with Two (2) 90o Elbows

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

One 90o elbow = Two 45o elbows.

Option

 

V

H

V + V1

With these options,

 

 

 

 

 

max. total pipe length is

A)

1'

Min.

4' Max.

2' Min.

30feetwithmin.of6feet

B)

2'

Min.

5' Max.

3' Min.

total vertical and max. 8

 

 

 

 

 

feet total horizontal.

C)

3'

Min.

6' Max.

4' Min.

Pleasenotemin.1foot

D)

4'

Min.

7' Max.

5' Min.

between 90o elbows is

 

 

 

 

 

required.

E)

5'

Min.

8' Max.

6' Min.

 

Option

H + H1

V

With these options, max. total

 

 

 

 

pipe length is 30 feet with min.

A)

2'

Max.

2' Min.

of 6 feet total vertical and max.

B)

3'

Max.

3' Min.

6 feet total horizontal.

 

 

 

 

Please note min. 1 foot

C)

4'

Max.

4' Min.

between 90o elbows is

D)

5'

Max.

5' Min.

required.

E)

6'

Max.

6' Min.

 

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P48-2 Installation, Horizontal Venting with Three 3 90o Elbows, Vertical Venting with Two 2 90o Elbows