Regency P48-2 Installation, Venting Arrangements, Vertical Terminations, Propane & Natural Gas

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 21
Image 21
VERTICAL TERMINATIONS

INSTALLATION

VENTING ARRANGEMENTS

VERTICAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM

(Propane & Natural Gas)

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90o elbow and one 45o elbow, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.

Vent must be supported at offsets.

Firestops are required at each floor level and whenever passing through a wall.

Maintain clearances to combustibles.

Note: Must use optional rigid pipe adapter when using Simpson Dura-Vent pipe (Part # 510-994).

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

21

Page 21
Image 21
Regency P48-2 Installation, Venting Arrangements, Vertical Terminations, Simpson Dura-Ventdirect Vent Gs System