INSTALLATION
UNIT INSTALLATION WITH HORIZONTAL TERMINATION
Install the vent system according to the manufacturer's instructions included with the components.
1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
2)DirectVentpipeandfittingsaredesignedwith
3)Put a bead of silicone inside the outer section of the adapter and a bead of Stove Mate on the inner collar. Slip the adapter over the existing inner and outer fl ue collar and fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier). Level the fi replace and fasten it to the framing using nails or screws through the nailing strips.
4)Assemble the desired combination of pipe and elbows to the appliance adaptor and
Note:
a)
Diagram 1
Note: For best results and optimum performance with each approved venting system, it is highly recommended to apply
b)Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.
5)Mark the wall for a 11" x 11" (279mm x 279mm) square hole. The center of the square hole should line up with the center- line of the horizontal pipe. Cut and frame the 11 inch (279mm) square hole in the exterior wall where the vent will be terminated.
If the wall being penetrated is constructed of
Diagram 2
Note:
a)The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re.
b)The location of the horizontal vent terminationonanexteriorwallmustmeet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see diagram in "Exterior Vent Termination Locations" section.
6)The arrow on the vent cap should be pointing up. Insure that the
Note: If installing termination on a siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
Diagram 5
The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
7)Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble (Part # 1247) over the vent pipe.
8)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of
Diagram 6
9)Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7).
Diagram 7
Regency® | 23 |