Regency P48-2 Installation, Clearances, Clearance to Combustibles from, Side Wall, Mantel

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 8
Image 8
CLEARANCES

INSTALLATION

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

Back 0" (0mm)

Side 0" (0mm)

Floor 0" (0mm)

Caution Requirements

The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

Minimum Clearance from Top of Front Facing:

Mantel

min. 8"

(203mm)

Ceiling

39"

(990mm) from top of front facing

 

 

above louvers.

Side Wall:

6"

(152mm)

Horizontal Vent Clearances:

Top 2-1/2" (64mm)

Side 1-1/2" (38mm)

Bottom 1-1/2" (38mm)

Vertical Vent Clearances:

1-1/4" (32mm)

Alcove Clearances:

Max. Depth

36"

(914mm)

Min. Width

60"

(1524mm)

Min. Height

80"

(2032mm)

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Heat Release Kit

The HeatWave Duct Kit and the Heat Release Kit have different clearance and framin requirements, check the HeatWave and Heat Release manual for details.

8

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace