UNIT SPECIFICATIONS

INSTALLATION

6) Install standard and optional features. Refer

UNIT SPECIFICATIONS

to the following sections:

a) Brick Panels Installation b) Log Set Installation

c) Standard Flush Door d) Flush Louvers

e) Flush Trim f) Bay Door g) Bay Trim h) Bay Louvers i) Finishing trim

j) Double Screen Door k) Remote Control

l)Wall Switch

m)Wall Thermostat

n)Installing the Fan

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)The P48-2 Direct Vent Gas Fireplace is approvedforalcoveinstallations,whichmeet the clearances listed on this page.

7)Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label 51,000 (NG) Btu/h, 48,000 (LP) Btu/h) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)Whenselectingalocationforyourfireplace, ensure that the clearances outlined on this page are met.

2)Provide adequate clearances for servicing.

3)The appliance must be installed on a fl at, solid,continuoussurface(e.g.wood,metal, concrete).Thismaybethefloor,orraisedup on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or othercombustiblematerialotherthanwood fl ooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

4)The P48-2 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.

Diagram 1

A) Flat on Wall

B) Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

Note: For vent terminations see "Exterior Vent Termination Locations" section.

HEATWAVE

OPTIONAL

DUCT SYSTEM KIT

#946-556

The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.

OPTIONAL

HEAT RELEASE KIT

#946-570

The Heat Release Kit expels warm air from the fi replace to the outside of the building, allowing the fi replace to be operated with less heat entering the room. The kit may be used on either the left or right side.

HEARTH

A hearth is not mandatory, but is recommended for aesthetics and for added safety.

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

7