Regency P48-2 Installation, Standard Flush Door, Flush Louvers, Optional Flush Trim, Diagram

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 34
Image 34
STANDARD

INSTALLATION

STANDARD

FLUSH DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1.

FLUSH LOUVERS

1)Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the fi rebox.

2)Install the bottom louver by folding the louver down and then sliding the Bottom Louver bracket down onto the 2 pins on the base of the unit (diagram 1). Secure with 1 screw as per diagram 2.

Burner ON/OFF control box attached to

bottom fl ush louver.

Diagram 1

Diagram 2

Diagram 1

Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

OPTIONAL FLUSH TRIM

Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door.

Diagram 2

Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd and 3rd spring. See diagram 3.

Diagram 3

Note: Top and bottom louvers are different.

3)Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi replace. Using the 2 screws on the louver, secure the control box in place.

NOTE: Springs must always be OVER not under the gas line.

Screws on

Burner ON/OFF

louver bracket

control box

To remove the fl ush door, reverse the above steps.

34

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

Page 34
Image 34