MAINTENANCE
REMOVING VALVE
7)Remove the right and left side defl ectors by removing the 2 screws on each defl ector.
1)Shut off the gas supply.
2)Remove the louvers (and bay door if it has been installed).
3)Open the fl ush door and remove the door.
4)Remove the logs and side brick panels, if installed.
5)Remove the grate by lifting up and out.
Grate
6)Remove the burner by removing the screw on the left side and then slide the burner to the left and lift out.
Remove the screw on the left
side of the burner.
Right Side
Defl ector
Left Side
Defl ector
8)Remove the base brick panels.
9)Disconnect the inlet gas line.
10)Removethe10Phillipsheadscrewssecuring the valve tray assembly in place and then lift the entire assembly out.
Lift entire valve tray
assembly out.
11)Disconnect the 2 TP wires and the 2 TH wires from the valve.
12)Undo the pilot tube from the valve with a 7/16" wrench.
13)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.
14)Remove the Piezo igniter wire and push button assembly.
Thermopile | Thermocouple | Pilot Nut |
Wire | Wire |
|
15)Undo the "gas out" fl are nut with a 13/16" wrench.
16)Undo the "gas out" fl are fi tting with an 11/16" wrench.
17)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.
Slide the burner to the left and lift out.
Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.
Valve Tray
Assembly
Regency® | 45 |