Regency P48-2 Maintenance, Removing Valve, 1Shut off the gas supply, Grate, Valve Tray Assembly

Models: P48-2

1 52
Download 52 pages 41.93 Kb
Page 45
Image 45
REMOVING VALVE

MAINTENANCE

REMOVING VALVE

7)Remove the right and left side defl ectors by removing the 2 screws on each defl ector.

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it has been installed).

3)Open the fl ush door and remove the door.

4)Remove the logs and side brick panels, if installed.

5)Remove the grate by lifting up and out.

Grate

6)Remove the burner by removing the screw on the left side and then slide the burner to the left and lift out.

Remove the screw on the left

side of the burner.

Right Side

Defl ector

Left Side

Defl ector

8)Remove the base brick panels.

9)Disconnect the inlet gas line.

10)Removethe10Phillipsheadscrewssecuring the valve tray assembly in place and then lift the entire assembly out.

Lift entire valve tray

assembly out.

11)Disconnect the 2 TP wires and the 2 TH wires from the valve.

12)Undo the pilot tube from the valve with a 7/16" wrench.

13)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

14)Remove the Piezo igniter wire and push button assembly.

Thermopile

Thermocouple

Pilot Nut

Wire

Wire

 

15)Undo the "gas out" fl are nut with a 13/16" wrench.

16)Undo the "gas out" fl are fi tting with an 11/16" wrench.

17)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.

Slide the burner to the left and lift out.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

Valve Tray

Assembly

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

45

Page 45
Image 45
Regency P48-2 Maintenance, Removing Valve, 1Shut off the gas supply, Grate, Right Side Defl ector Left Side Defl ector