CAUTION: Never cover control knobs or surrounding control surface with utensils, towels, or other objects. Never obstruct free air passage past the control knobs. The knob openings have been sized to properly control air entry to the interior of the appliance during operation.

This appliance has no air shutters. Primary air adjustments are unnecessary. The burners are designed to provide optimum aeration for all gases without air

shutters. When operating properly, burners should produce clearly defined, even blue flames. If the flames have yellow tips or are hazy and otherwise appear to have insufficient air, obtain the services of a qualified service technician. Some yellow tipping on LP gas is normal.

Specified input rates are as shown in figures 16 and 17 below.

5 BURNER MODEL (36Wide)

4 BURNER MODEL (30Wide)

FIGURE 16

JENN- AIR 36

INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)

BURNER LOCATION

Hi

 

Lo

 

 

 

 

Right Front

17,000

/ 14,000

2,200/2,200

Right Rear

9,200

/

9,100

1,500 / 1,500

Left Front

9,200

/

9,200

1,500 / 1,500

Left Rear

12,000

/ 10,500

1,500 / 1,500

Center

5,000

/

4,000

1,100 / 1,100

 

 

 

 

 

FIGURE 17

JENN- AIR 30

INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)

BURNER LOCATION

Hi

 

 

Lo

 

 

 

 

 

Right Front

17,000

/ 14,000

1,800

/ 1,800

Right Rear

9,200

/

9,100

1,300

/ 1,300

Left Front

12,000

/ 10,500

1,300

/ 1,300

Left Rear

5000

/

4000

650

/ 650

Center

----------

------------

----------------------

 

 

 

 

 

 