Jenn-Air JMW3430W, JMW2430W Opening/Clearance Dimensions, Jenn-Air Detailed Planning Dimensions

Models: JMW2330W JMW2430W JMW3430W

1 4
Download 4 pages 1.86 Kb
Page 3
Image 3
OPENING/CLEARANCE DIMENSIONS

JENN-AIR®DETAILED PLANNING DIMENSIONS

3 of 4

30" combination microwave/wall ovens

JMW3430W, JMW2430W, JMW2330W – 2934" x 4318" x 2634"

OPENING/CLEARANCE DIMENSIONS

A

D

C

B

E

e

F

FRONT VIEW

G

Side VIEW

 

 

 

JMW3430W

 

 

 

JMW2430W

MODEL #

 

JMW2330W

 

 

 

 

 

 

 

 

in

cm

 

 

 

 

 

A

Width of cabinet (min.)

 

30

76.2

 

 

 

 

 

B

Width of cutout

 

2812

72.4

C

Height of cutout

 

4114

104.8

D

Top of cutout to bottom

 

2

5.1

of upper cabinet door (min.)

 

 

 

 

 

 

 

 

 

 

E

Bottom of cutout to top

 

112

3.8

of lower cabinet door (min.)

 

 

 

 

 

 

 

 

 

 

F

Bottom of cutout to floor

 

458-

11.7-

 

1914

48.9

 

 

 

G

Depth of cutout (min.)

 

24

61.0

 

 

 

 

 

e

Recommended junction box location

 

 

 

 

 

 

 

ELECTRICAL REQUIREMENTS

240 volt, 40-amp fused, grounded circuit is required. A dedicated circuit is recommended.

The length of conduit provided is for serviceability. Do not cut the conduit. The junction box should be located 3" (7.6 cm) maximum below the support surface. Drill a 114" (3.4 cm) minimum diameter hole in the left rear corner of the support surface for access to the junction box.

Power Supply Location

Back VIEW

Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing

JRC120003A 07/2012

any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

Page 3
Image 3
Jenn-Air JMW3430W Opening/Clearance Dimensions, Jenn-Air Detailed Planning Dimensions, combination microwave/wall ovens