4 of 4 |
30" combination microwave/wall ovens – Flush Installation
JMW3430W, JMW2430W, JMW2330W – 293⁄4" x 431⁄8" x 243⁄4" (depth without handles)
OPENING/CLEARANCE DIMENSIONS
JMW3430W |
JMW2430W |
| 21⁄16" (5.2 cm) |
| Top Cleat* |
| A |
| B |
C |
|
D |
|
3⁄4" (1.9 cm) | 3⁄4" (1.9 cm) |
Side Cleat* | Side Cleat* |
| 11⁄2" (3.8 cm) |
| Platform* |
e |
|
| E |
FRONT VIEW
F |
Side VIEW
MODEL # | JMW2330W | |||
|
|
|
| |
|
| in | cm | |
|
|
|
| |
A | Width of flush inset cutout (min.) | 30 | 76.2 | |
|
|
|
| |
B | Width of opening (min.) | 281⁄2 | 72.4 | |
C | Height of flush inset cutout (min.) | 4413⁄16 | 113.8 | |
D | Height of opening (min.) | 411⁄4 | 104.8 | |
E | Bottom of cutout to floor | 45⁄8- | 11.7- | |
191⁄4 | 48.9 | |||
|
| |||
F | Depth of cutout (min.) | 25 | 63.5 | |
|
|
|
| |
e | Recommended junction box location |
|
| |
|
|
|
|
ELECTRICAL REQUIREMENTS
240 volt,
The length of conduit provided is for serviceability. Do not cut the conduit. The junction box should be located 3" (7.6 cm) maximum below the support surface. Drill a 11⁄4" (3.4 cm) minimum diameter hole in the left rear corner of the support surface for access to the junction box.
Flush Installation Requirements
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 3⁄8" (1.0 cm) reveal on the top,
a 1⁄8" (0.3 cm) reveal on the sides and a 13⁄8" (3.5 cm) reveal on the bottom of the wall oven.
The front face of the cleats and platform will be visible and should be treated as a finished surface.
Power Supply Location
| F |
Side Cleat* | Side Cleat* |
1" (2.5 cm) |
|
TOP VIEW | Back VIEW |
*Cleats and platform must be recessed 1" (2.5 cm) from the front of the cabinet.
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing | JRC120003A 07/2012 |
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary. |