Jenn-Air JXT8042ADS specifications INSTALLATION7, Ductless Conversion

Models: JXT8042ADS

1 24
Download 24 pages 22.45 Kb
Page 8
Image 8
INSTALLATION7

INSTALLATION7

DUCTLESS CONVERSION

Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and exhaust from cooking is drawn and filtered by a set of optional Carbon Filters. The air is then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an Exhaust unit. Only when the exhaust option is not possible should you recourse to converting the hood into a "purifying"unit.

When converted to be a "purifying" unit, a set of Carbon Filters are required on top of its standard Metal Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture residue from cooking and the optional Carbon Filters help to purify fumes exhausted from cooking for re-circulation.

Carbon Filters (Required)

1. Purchase ductless Carbon Filters as follows:

Hood Model:

Part No.

Filters in pkg.

JXT8030ADS JFLTRC8030 2

JXT8036ADS JFLTRC8036 3

JXT8042ADS JFLTRC8036 3

2. Remove metal filters on hood. Clip carbon filters onto each slot opening.

3. Re-install metal filters.

4. Set filter change reminder for carbon filters.

When Off, hold DUCTLESS CONVERSIONManual backgroundManual backgroundManual backgroundManual backgroundManual background for approx. 5 seconds. The display will change from Manual backgroundManual backgroundManual backgroundManual background

(exhaust mode) to Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background , (purifying mode/

carbon filters used) this indicates that the

elapse timer function is switched on and

Carbon Filter Dimensions:

Carbon Filters are used.

8.98 in x 6.38 in

5. Carbon Filters must be replaced after

228 mm x 162 mm

 

every 120 hours of use (or approximately

 

every 2 to 3 months based on the average

 

of 1-2 hrs. of daily cooking time). The

 

microprocessor in the controls when set,

 

will count usage time and indicate when

 

carbon filter replacement is required.

6" T connector

 

or 90 elbow

Ducting

6" straight pipe

 

1. Install a 6" straight pipe and a "T" connector/

wall pipe strap

or a 90 elbow to divert air through louvers on

 

duct cover.

 